Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device

被引:61
作者
Gheno, Ramon [1 ,2 ]
Nectoux, Eric [3 ]
Herbaux, Bernard [3 ]
Baldisserotto, Matteo [4 ]
Glock, Luiz [5 ]
Cotten, Anne [2 ]
Boutry, Nathalie [6 ]
机构
[1] Hop Roger Salengro, Serv Radiol Osteoarticulaire, F-59037 Lille, France
[2] Hop Roger Salengro, Ctr Hosp Reg Univ Lille, Dept Musculoskeletal Radiol, F-59037 Lille, France
[3] Hop Jeanne Flandre, Ctr Hosp Reg Univ Lille, Dept Pediat Surg & Orthopaed, Lille, France
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Radiol, Porto Alegre, RS, Brazil
[5] Pontificia Univ Catolica Rio Grande do Sul, Dept Stat, Porto Alegre, RS, Brazil
[6] Hop Roger Salengro & Jeanne de Flandre, Ctr Hosp Reg Univ Lille, Dept Musculoskeletal & Pediat Radiol, Lille, France
关键词
Three-dimensional; Lower extremity; Measure; Children; Adolescent; LIMB-LENGTH DISCREPANCY; COMPUTED-TOMOGRAPHY; STANDING POSITION; KNEE REPLACEMENT; RADIATION; ALIGNMENT; CT; CAMPAIGN; SPINE;
D O I
10.1007/s00330-011-2308-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To evaluate three-dimensional (3D) measurements of the lower extremity using a biplanar low-dose X-ray device in children and adolescents. Firstly, 3D measurements of eight dried bones were analysed by a biplanar low-dose X-ray device (LDX) using stereoscopic software and compared with 3D computed tomography (CT). Secondly, 47 lower limbs of children and adolescents were studied using LDX two-dimensional (2D) and 3D measurements. Both parts were evaluated for femoral and tibial lengths and mechanical angles, frontal and lateral knee angulations, and the femoral neck-shaft angle. The 3D specimen comparison between LDX and CT measurements showed no significant differences: femoral length (P = 0.069), tibial length (P = 0.059), femoral mechanical angle (P = 0.475), tibial mechanical angle (P = 0.067), frontal knee angulation (P = 0.198), lateral knee angulation (P = 0.646) and femoral neck-shaft angle (P = 0.068). The comparison between LDX 2D and 3D measurements showed significant differences in tibial length (P = 0.003), femoral mechanical angle (P < 0.001) and femoral neck-shaft angle (P = 0.001); other parameters were unremarkable. The 3D LDX system presented reliable measurements compared with 3D CT. Differences between LDX 2D and 3D measurements were noted in the femoral mechanical angle, femoral neck-shaft angle and tibial length. Moderate to good interobserver agreement for the 3D LDX measurements were found. aEuro cent Low radiation dose is essential when assessing potential lower extremity discrepancies aEuro cent A new biplanar low-dose X-ray device can assess such discrepancies in children/adolescents aEuro cent This LDX device provides equally reliable 3D measurements as prevalent practice LDX measurements carry good overall interobserver agreement.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 38 条
[1]
COMPARISON OF ORTHOROENTGENOGRAPHY AND COMPUTED-TOMOGRAPHY IN THE MEASUREMENT OF LIMB-LENGTH DISCREPANCY [J].
AARON, A ;
WEINSTEIN, D ;
THICKMAN, D ;
EILERT, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :897-902
[2]
LEG LENGTH DETERMINATION BY CT DIGITAL RADIOGRAPHY [J].
AITKEN, AGF ;
FLODMARK, O ;
NEWMAN, DE ;
KILCOYNE, RF ;
SHUMAN, WP ;
MACK, LA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (03) :613-615
[3]
Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects [J].
Ariumi, Akihiro ;
Sato, Takashi ;
Kobayashi, Koichi ;
Koga, Yoshio ;
Omori, Go ;
Minato, Izumi ;
Endo, Naoto .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (01) :64-70
[4]
Azmy C, 2010, ORTHOP TRAUMATOL-SUR, V96, P27, DOI [10.1016/j.otsr.2009.10.013, 10.1016/j.rcot.2009.12.003]
[5]
Personalized models of bones based on radiographic photogrammetry [J].
Berthonnaud, E. ;
Hilmi, R. ;
Dimnet, J. .
SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (06) :461-470
[6]
Image Wisely: A Campaign to Increase Awareness about Adult Radiation Protection [J].
Brink, James A. ;
Amis, E. Stephen, Jr. .
RADIOLOGY, 2010, 257 (03) :601-602
[7]
Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays [J].
Chaibi, Y. ;
Cresson, T. ;
Aubert, B. ;
Hausselle, J. ;
Neyret, P. ;
Hauger, O. ;
de Guise, J. A. ;
Skalli, W. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) :457-466
[8]
Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[9]
Optimizing Limb Position for Measuring Knee Anatomical Axis Alignment from Standing Knee Radiographs [J].
Cooke, T. Derek V. ;
Sled, Elizabeth A. .
JOURNAL OF RHEUMATOLOGY, 2009, 36 (03) :472-477
[10]
Alternative reliable techniques in femoral torsion measurement [J].
Delialioglu, MO ;
Tasbas, BA ;
Bayrakci, K ;
Daglar, B ;
Kurt, M ;
Agar, M ;
Gunel, U .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2006, 15 (01) :28-33