Accurate mass measurements by Fourier transform mass spectrometry

被引:100
作者
Zhang, LK
Rempel, D
Pramanik, BN
Gross, ML [1 ]
机构
[1] Washington Univ, Dept Chem, St Louis, MO 63130 USA
[2] Schering Plough Res Inst, Kenilworth, NJ USA
关键词
accurate (exact) mass measurement; Fourier transform (ion cyclotron resonance) mass spectrometry; mass calibration; space-charge (Coulombic) effects; Coulombic effects; MALDI; electrospray ionization;
D O I
10.1002/mas.20013
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The capability for accurate mass measurements is an important attribute of Fourier transform mass spectrometry (FTMS). Unlike other instrumental methods in mass spectrometry, FTMS still offers significant opportunities to improve mass measurement accuracy (MMA), making it an area of research. This review covers the published literature in FTMS from the late 1970s to the present. We discuss the development and evolution of mass calibration that give accuracies in the low ppm range. We sketch the derivation and show the common foundation of these mass calibration procedures. We also describe the relation of mass calibration and the fundamentals of ion motion and space-charge effects, and we review efforts to improve the basic calibration procedure particularly those that correct for effects of space charge. The advent of matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) have opened the door for FTMS to be used for analyzing at high performance biopolymers, including proteins, oligodeoxynucleotides (ODNs), oligosaccharides, and synthetic polymers. We also discuss the utility of FTMS for accurate mass measurement in these areas and some practical ways to improve MMA. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:286 / 309
页数:24
相关论文
共 137 条
[31]   A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry [J].
Hannis, JC ;
Muddiman, DC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (10) :876-883
[32]   EXTERNAL-ION ACCUMULATION IN A PENNING TRAP WITH QUADRUPOLE EXCITATION ASSISTED BUFFER GAS-COOLING [J].
HASSE, HU ;
BECKER, S ;
DIETRICH, G ;
KLISCH, N ;
KLUGE, HJ ;
LINDINGER, M ;
LUTZENKIRCHEN, K ;
SCHWEIKHARD, L ;
ZIEGLER, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03) :181-191
[33]  
Hendrickson CL, 1996, RAPID COMMUN MASS SP, V10, P1829, DOI 10.1002/(SICI)1097-0231(199611)10:14<1829::AID-RCM697>3.0.CO
[34]  
2-U
[35]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449
[36]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION [J].
HENRY, KD ;
WILLIAMS, ER ;
WANG, BH ;
MCLAFFERTY, FW ;
SHABANOWITZ, J ;
HUNT, DF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9075-9078
[37]   MATRIX-ASSISTED LASER DESORPTION FOURIER-TRANSFORM MASS-SPECTROMETRY FOR THE STRUCTURAL EXAMINATION OF MODIFIED NUCLEIC-ACID CONSTITUENTS [J].
HETTICH, RL ;
BUCHANAN, MV .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 111 :365-380
[38]  
Hofstadler SA, 1998, RAPID COMMUN MASS SP, V12, P1400, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1400::AID-RCM337>3.0.CO
[39]  
2-T
[40]   SUSPENDED TRAPPING PROCEDURE FOR ALLEVIATION OF SPACE-CHARGE EFFECTS IN GAS-CHROMATOGRAPHY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
HOGAN, JD ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :530-535