The Aun cluster probe in secondary ion mass spectrometry:: influence of the projectile size and energy on the desorption/ionization rate from biomolecular solids

被引:42
作者
Novikov, A
Caroff, M
Della-Negra, S
Depauw, J
Fallavier, M
Le Beyec, Y
Pautrat, M
Schultz, JA
Tempez, A
Woods, AS
机构
[1] Inst Phys Nucl, CNRS, F-91406 Orsay, France
[2] Univ Paris 11, IBBMC, Equipe Endotoxines, CNR UMR 8619, F-91405 Orsay, France
[3] Univ Lyon 1, Inst Phys Nucl Lyon, CNRS, F-69622 Villeurbanne, France
[4] Ionwerks Inc, Houston, TX 77030 USA
[5] NIDA, IRP, Baltimore, MD 21224 USA
关键词
D O I
10.1002/rcm.1995
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A Au-Si liquid metal ion source which produces Au-n clusters over a large range of sizes was used to study the dependence of both the molecular ion desorption yield and the damage cross-section on the size (n = 1 to 400) and on the kinetic energy (E = 10 to 500 keV) of the clusters used to bombard bioorganic surfaces. Three pure peptides with molecular masses between 750 and 1200Da were used without matrix. [M+H](+) and [M+cation](+) ion emission yields were enhanced by as much as three orders of magnitude when bombarding with Au-400(4+) instead of monatomic Au+, yet very little damage was induced in the samples. A 100-fold increase in the molecular ion yield was observed when the incident energy of Au-9(+) was varied from 10 to 180 keV. Values of emission yields and damage cross-sections are presented as a function of cluster size and energy. The possibility to adjust both cluster size and energy, depending on the application, makes the analysis of biomolecules by secondary ion mass spectrometry an extremely powerful and flexible technique, particularly when combined with orthogonal time-of-flight mass spectrometry that then allows fast measurements using small primary ion beam currents. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:1851 / 1857
页数:7
相关论文
共 35 条
[1]   NONLINEAR EFFECTS IN HEAVY-ION SPUTTERING [J].
ANDERSEN, HH ;
BAY, HL .
JOURNAL OF APPLIED PHYSICS, 1974, 45 (02) :953-954
[2]   Gold-cluster ranges in aluminium, silicon and copper [J].
Andersen, HH ;
Johansen, A ;
Olsen, M ;
Touboltsev, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 212 :56-62
[3]   FOCUSED, RASTERABLE, HIGH-ENERGY NEUTRAL MOLECULAR-BEAM PROBE FOR SECONDARY ION MASS-SPECTROMETRY [J].
APPELHANS, AD ;
DELMORE, JE ;
DAHL, DA .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1685-1691
[4]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[5]   Multi-anode detection in electrospray ionization time-of-flight mass spectrometry [J].
Barbacci, DC ;
Russell, DH ;
Schultz, JA ;
Holocek, J ;
Ulrich, S ;
Burton, W ;
Van Stipdonk, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (12) :1328-1333
[6]  
Barlo Daya D. D. N., 1995, NUCL INSTRUM METH B, V106, P38, DOI [10.1016/0168-583X(95)00674-5, DOI 10.1016/0168-583X(95)00674-5]
[7]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[8]  
BLAIN M, 1989, PHYS REV LETT, V15, P1625
[9]   SECONDARY-ION YIELDS FROM SURFACES BOMBARDED WITH KEV MOLECULAR AND CLUSTER IONS [J].
BLAIN, MG ;
DELLANEGRA, S ;
JORET, H ;
LEBEYEC, Y ;
SCHWEIKERT, EA .
PHYSICAL REVIEW LETTERS, 1989, 63 (15) :1625-1628
[10]   Very large gold and silver sputtering yields induced by keV to MeV energy Aun clusters (n=1-13) -: art. no. 144106 [J].
Bouneau, S ;
Brunelle, A ;
Della-Negra, S ;
Depauw, J ;
Jacquet, D ;
Le Beyec, Y ;
Pautrat, M ;
Fallavier, M ;
Poizat, JC ;
Andersen, HH .
PHYSICAL REVIEW B, 2002, 65 (14) :1-8