Navigated pedicle screw placement:: Experimental comparison between CT- and 3D fluoroscopy-based techniques

被引:54
作者
Geerling, Jens [1 ]
Goesling, Thomas [1 ]
Goesling, Anna [1 ]
Ortega, Gil [2 ]
Kendoff, Daniel [1 ]
Citak, Musa [1 ]
Krettek, Christian [1 ]
Huefner, Tobias [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
[2] Scottsdale Healthcare, Dept Orthopaed, Sonoran Orthopaed Trauma Surg, Scottsdale, AZ USA
关键词
Iso-C3D navigation; pedicle screw; accuracy analysis;
D O I
10.3109/10929080802102110
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Even with CT-based navigation, the misplacement rate for pedicle screws is reported to be as high as 10%. Using fluoroscopy-based 3D navigation, misplacement rates of 1.7 to 6% occur. The purpose of this study was to compare the accuracy of CT-based and Iso-C-based navigation in an experimental context. Methods: A foam spine model and the SurgiGATE(R) navigation system were used. First, a determination of point accuracy measured the difference between the real positions of markers placed on selected vertebrae and their positions as determined by the navigation system. In the verification mode, the pointer is placed exactly on the markers displayed on the monitor screen, and the deviation of the pointer tip and marker is measured in reality using a caliper. Secondly, pedicle accuracy was measured using pre-drilled holes for pedicle screws. A trajectory was planned into the visible hole and the navigated pointer was placed. Results: The measured accuracy for the markers showed a statistically significant difference between the results with CT and Iso-C navigation for one of six markers placed on the vertebra. Iso-C-based navigation demonstrated a lower mean deviation of 0.5 mm, compared to 1 mm with CT-based navigation. The deviation within the pre-drilled holes was lower when using the Iso-C3D scan. Using Iso-C3D navigation, 76.6% of the measurements showed no deviation at the entrance point, compared with 43% when using CT-based navigation. Also, with Iso-C3D navigation, 78.3% of the inserted pedicle awls hit the defined trajectories in the pre-drilled holes correctly, compared to 66.6% with CT-based navigation. Conclusion: The overall image-to-reality accuracy for CT- and Iso-C-based navigation was assessed in the described experimental setup. An apparent tendency towards higher accuracy with Iso-C-based navigation was evaluated; however, the differences were not significant.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 46 条
[1]
COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY [J].
AMIOT, LP ;
LABELLE, H ;
DEGUISE, JA ;
SATI, M ;
BRODEUR, P ;
RIVARD, CH .
SPINE, 1995, 20 (10) :1208-1212
[2]
Computer-guidance in percutaneous screw stabilization of the iliosacral joint [J].
Arand, M ;
Kinzl, L ;
Gebhard, F .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (422) :201-207
[3]
Arand M, 2001, Comput Aided Surg, V6, P170, DOI 10.3109/10929080109146003
[4]
Pitfalls and risks of navigation based on computed tomography [J].
Arand, M ;
Kinzl, L ;
Gebhard, F .
ORTHOPADE, 2002, 31 (04) :378-384
[5]
Precision, standarized Iso-C-arm based navigated boring on the proximal femur [J].
Arand, M ;
Schempf, M ;
Kinzl, L ;
Fleiter, T ;
Pless, D ;
Gebhard, F .
UNFALLCHIRURG, 2001, 104 (12) :1150-1156
[6]
BANTA CJ, 1989, ORTHOPEDICS, V12, P939
[7]
In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[8]
Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction [J].
Berlemann U. ;
Heini P. ;
Müller U. ;
Stoupis C. ;
Schwarzenbach O. .
European Spine Journal, 1997, 6 (6) :406-410
[9]
Citak M, 2006, Technol Health Care, V14, P473
[10]
Dickman C A, 2000, Clin Neurosurg, V47, P495