Amberlite XAD-2 functionalized with Nitroso R salt: synthesis and application in an online system for preconcentration of cobalt

被引:43
作者
Lemos, VA [1 ]
Santos, JS [1 ]
Nunes, LS [1 ]
de Carvalho, MB [1 ]
Baliza, PX [1 ]
Yamaki, RT [1 ]
机构
[1] Univ Estadual SE Bahia, LQA, Dept Quim & Exatas, BR-45200000 Jequie Bahia, Brazil
关键词
preconcentration; cobalt; amberlite XAD-2; nitroso R salt; online; flame atomic absorption spectrometry;
D O I
10.1016/j.aca.2003.08.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The synthesis and characterization of the resin Amberlite XAD-2 functionalized with Nitroso R salt and its application in an online system for preconcentration of cobalt and determination by flame atomic absorption spectrometry (FAAS) is proposed. Cobalt(II) ions are sorbed in a minicolumn packed with the synthesized solid phase. Thereafter, these ions are eluted by acid solution to the nebulizer of a flame atomic absorption spectrometer. Sample throughput is 51 h(-1) or 18 h(-1), depending on preconcentration time, 60 s or 180 s, respectively. Cobalt was determined at pH 6.5-8.0, using a sample flow rate of 9.5 ml min(-1). Elution was performed with 30 mul of 1.0 mol l(-1) hydrochloric acid. The enrichment factors obtained were 79 and 223, with 3sigma detection limits of 1.25 and 0.39 mug l(-1), for respective preconcentration periods of 60 and 180 s. The accuracy of the procedure was evaluated by analysis of biological certified material. The method was successfully applied for cobalt determination in natural water samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 49 条
[1]   Cobalt ultra-trace on-line preconcentration and determination using a PTFE turnings packed column and electrothermal atomic absorption spectrometry. Applications in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1330-1334
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE-ELEMENTS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CAROLI, S ;
ALIMONTI, A ;
PETRUCCI, F ;
HORVATH, Z .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :241-249
[4]   Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC) [J].
Cassella, RJ ;
Salim, VA ;
Jesuíno, LS ;
Santelli, RE ;
Ferreira, SLC ;
de Carvalho, MS .
TALANTA, 2001, 54 (01) :61-67
[5]   Determination of ultra-trace amounts of cadmium, cobalt and nickel in sea-water by electrothermal atomic absorption spectrometry with on-line preconcentration [J].
Chang, HJ ;
Sung, YH ;
Huang, SD .
ANALYST, 1999, 124 (11) :1695-1699
[6]   Determination of cobalt and nickel in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 434 (02) :325-330
[7]   ONLINE PRECONCENTRATION OF SILVER ON ACTIVATED ALUMINA AND DETERMINATION IN BOREHOLE WATER BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROPHOTOMETRY [J].
COETZEE, PP ;
TALJAARD, I ;
DEBEER, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (03) :201-204
[8]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[9]  
FANG Z, 1993, FLOW INJECTIN SEPARA
[10]   FUNDAMENTAL AND PRACTICAL CONSIDERATIONS IN THE DESIGN OF ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC SPECTROMETRIC SYSTEMS [J].
FANG, ZL ;
XU, SK ;
ZHANG, SC .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :35-49