Two-phase reconstruction for the assessment of left ventricular volume and function using retrospective ECG-gated MDCT: Comparison with echocardiography

被引:25
作者
Kim, TH
Hur, J
Kim, SJ
Kim, HS
Choi, BW
Choe, KO
Yoon, YW
Kwon, HM
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Yongdong Severance Hosp, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Dept Cardiol, Yongdong Severance Hosp, Seoul, South Korea
关键词
D O I
10.2214/ajr.185.2.01850319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aims of our study were to investigate the clinical feasibility of a two-phase reconstruction method based on ECG to evaluate left ventricular (LV) volume and function using cardiac MDCT and to compare these results with those from echocardiography. SUBJECTS AND METHODS. The LV end-diastolic and end-systolic volumes, stroke volume, and ejection fraction were measured using two different methods of cardiac MDCT in 19 patients who had undergone cardiac MDCT and echocardiography. The first was a two-phase reconstruction method based on retrospective ECG-triggering: The end-systolic phase was reconstructed when the reconstruction window was located halfway in the ascending T wave on ECG, and the end-diastolic phase was reconstructed when the reconstruction window was located at the starting point of the QRS complex on ECG. The second was a multiphase reconstruction method: 20 series of images were reconstructed at every 5% throughout the cardiac cycle. The LV volumes and function determined by the two reconstruction methods were compared. The results measured by cardiac MDCT were compared with those obtained by echocardiography. RESULTS. The LV end-diastolic and end-systolic volumes, stroke volume, and ejection fraction measured by the two-phase reconstruction method correlated well with those measured by the multiphase reconstruction method (r = 0.984, 0.978, 0.969, 0.969, respectively). There were no significant differences between the results of the two different reconstruction methods (p > 0.05). The LV volumes showed moderate to good correlation between cardiac MDCT and echocardiography (0.766 < r < 0.940). Ejection fraction measured by cardiac MDCT yielded a significant overestimation of 2.9% +/- 8.7% (mean +/- SD) compared with that measured by echocardiography. CONCLUSION. A two-phase reconstruction method on cardiac MDCT is relatively simple and can provide an objective standard for reconstructing the appropriate image sets for end-diastole and end-systole without the need to review serial preview images.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 20 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[3]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[4]   Evaluation of regional differences in right ventricular systolic function by acoustic quantification echocardiography and cine magnetic resonance imaging [J].
Geva, T ;
Powell, AJ ;
Crawford, EC ;
Chung, T ;
Colan, SD .
CIRCULATION, 1998, 98 (04) :339-345
[5]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[6]   LEFT-VENTRICULAR DYSFUNCTION AFTER ACUTE MYOCARDIAL-INFARCTION - RESULTS OF A PROSPECTIVE MULTICENTER STUDY [J].
GREENBERG, H ;
MCMASTER, P ;
DWYER, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (05) :867-874
[7]   Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging [J].
Grude, M ;
Juergens, KU ;
Wichter, T ;
Paul, M ;
Fallenberg, EM ;
Muller, JG ;
Heindel, W ;
Breithardt, G ;
Fischbach, R .
INVESTIGATIVE RADIOLOGY, 2003, 38 (10) :653-661
[8]   PROGNOSTIC AND PREDICTIVE VALUE OF EXERTIONAL HYPOTENSION IN SUSPECTED CORONARY HEART-DISEASE [J].
HAMMERMEISTER, KE ;
DEROUEN, TA ;
DODGE, HT ;
ZIA, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (08) :1261-1266
[9]   Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality [J].
Herzog, C ;
Abolmaali, N ;
Balzer, JO ;
Baunach, S ;
Ackermann, H ;
Dogan, S ;
Britten, MB ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2670-2678
[10]   Using ECG-gated multicletector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease [J].
Juergens, KU ;
Grude, M ;
Fallenberg, EM ;
Opitz, C ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1545-1550