Semiautomatic Quantification of Left Ventricular Function by Two-Dimensional Feature Tracking Imaging Echocardiography. A Comparison Study with Cardiac Magnetic Resonance Imaging

被引:9
作者
Di Bella, Gianluca [1 ]
Zito, Concetta [1 ]
Gaeta, Michele [2 ]
Piccione, Maurizio Cusma [1 ]
Minutoli, Fabio [2 ]
Donato, Rocco [2 ]
Recupero, Antonino [1 ]
Madaffari, Antonio [1 ]
Coglitore, Sebastiano [1 ]
Carerj, Scipione [1 ]
机构
[1] Univ Messina, Clin & Expt Dept Med & Pharmacol, Messina, Italy
[2] Univ Messina, Dept Radiol Sci, Messina, Italy
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2010年 / 27卷 / 07期
关键词
transthoracic echocardiography; feature tracking imaging echocardiography; speckle tracking imaging; left ventricular volumes; ejection fraction; cardiac magnetic resonance imaging; 3-DIMENSIONAL ECHOCARDIOGRAPHY; CLINICAL-DIAGNOSIS; EJECTION FRACTION; VALIDATION; STRAIN; VOLUME; DEFIBRILLATOR; IMPLANTATION; QUANTITATION;
D O I
10.1111/j.1540-8175.2009.01136.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the accuracy of a semiautomatic quantification of left ventricular (LV) volumes and ejection fraction (EF) using two-dimensional (2D) feature tracking imaging (FTI). Methods: Thirty-four consecutive subjects (11 patients with dilated cardiomyopathy, 13 with hypertrophic cardiomyopathy, and 10 subjects with no cardiac disease) underwent, on the same day, trans-thoracic echocardiography (TTE) examination, FTI, and cardiac magnetic resonance imaging (MRI), as gold standard, in order to quantify LV volumes and EF. The echocardiographic quantification of LV volumes and EF was determined from four- and two-chamber views using both standard TTE Biplane Simpson's method and a semiautomatic border detection based on FTI. Furthermore, the time for data analysis for each method was measured. Results: The time required for semiautomatic analysis of volumes and EF was significantly lower (P < 0.0001) by FTI (71 seconds) in comparison with standard biplane Simpson's method (93 seconds). LV volumes obtained by FTI were significant underestimated (P < 0.001) in comparison with MRI. Bland-Altman analysis of EDV and ESV using FTI and cardiac MRI showed a low level of agreement for EDV (mean difference = 40.8; SD = 39) and ESV (mean difference = 38.1; SD = 42). On the contrary, no significant difference between FTI and MRI in assessing the LVEF was found; furthermore, a very low bias (2 +/- 12) by Bland-Altman analysis was found between FTI and cardiac MRI for the quantification of EF. Conclusion: Semiautomatic quantification of LV volumes using FTI allows an accurate, rapid, easy and reliable assessment of LV EF and a rough estimation of LV volumes. (Echocardiography 2010;27:791-797).
引用
收藏
页码:791 / 797
页数:7
相关论文
共 24 条
  • [1] Left Ventricular Functional Analysis With 16-and 64-Row Multidetector Computed Tomography: Comparison With Gated Single-Photon Emission Computed Tomography
    Agarwal, Prachi P.
    Patel, Smita
    Corbett, James
    Jung, Jung Im
    Barber, Karen
    Schipper, Matthew
    Kazerooni, Ella A.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (01) : 8 - 14
  • [2] A new 2D-based method for myocardial velocity strain and strain rate quantification in a normal adult and paediatric population: assessment of reference values
    Bussadori, C.
    Moreo, A.
    Di Donato, M.
    De Chiara, B.
    Negura, D.
    Dall'Aglio, E.
    Lobiati, E.
    Chessa, M.
    Arcidiacono, C.
    Dua, J. S.
    Mauri, F.
    Carminati, M.
    [J]. CARDIOVASCULAR ULTRASOUND, 2009, 7
  • [3] CMR of ventricular function
    Keenan, Niall G.
    Pennell, Dudley J.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (02): : 185 - 193
  • [4] The Value of 2D Strain Imaging during Stress Testing
    Moonen, Marie
    Lancellotti, Patrizio
    Zacharakis, Dimitrios
    Pierard, Luc
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (03): : 307 - 314
  • [5] Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    Moss, AJ
    Zareba, W
    Hall, WJ
    Klein, H
    Wilber, DJ
    Cannom, DS
    Daubert, JP
    Higgins, SL
    Brown, MW
    Andrews, ML
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) : 877 - 883
  • [6] Strain and Strain Rate Imaging in Cardiomyopathy
    Nesbitt, Gillian C.
    Mankad, Sunil
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (03): : 337 - 344
  • [7] Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI
    Nesser, Hans-Joachim
    Mor-Avi, Victor
    Gorissen, Willem
    Weinert, Lynn
    Steringer-Mascherbauer, Regina
    Niel, Johannes
    Sugeng, Lissa
    Lang, Roberto M.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (13) : 1565 - 1573
  • [8] Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography
    Nishikage, Tomoko
    Nakai, Hiromi
    Mor-Avi, Victor
    Lang, Roberto M.
    Salgo, Ivan S.
    Settlemier, Scott H.
    Husson, Stephane
    Takeuchi, Masaaki
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : 82 - 88
  • [9] Fast Data Acquisition and Analysis with Real Time Triplane Echocardiography for the Assessment of Left Ventricular Size and Function: A Validation Study
    Nucifora, Gaetano
    Badano, Luigi P.
    Dall'Armellina, Erica
    Gianfagna, Pasquale
    Allocca, Giuseppe
    Fioretti, Paolo M.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (01): : 66 - 75
  • [10] Economic and biological costs of cardiac imaging
    Picano E.