Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI

被引:194
作者
Nesser, Hans-Joachim [2 ]
Mor-Avi, Victor [1 ]
Gorissen, Willem [3 ]
Weinert, Lynn [1 ]
Steringer-Mascherbauer, Regina [2 ]
Niel, Johannes [2 ]
Sugeng, Lissa [1 ]
Lang, Roberto M. [1 ]
机构
[1] Univ Chicago, Chicago, IL 60637 USA
[2] Publ Hosp Elisabethinen, Linz, Austria
[3] Toshiba Med Syst, Zoetermeer, Netherlands
关键词
Echocardiography; Magnetic resonance imaging; Left ventricle; CARDIAC RESYNCHRONIZATION THERAPY; AGE-RELATED-CHANGES; RADIAL STRAIN; MYOCARDIAL-INFARCTION; LONGITUDINAL STRAIN; DILATED CARDIOMYOPATHY; EJECTION FRACTION; TISSUE DOPPLER; HEART-FAILURE; DYSSYNCHRONY;
D O I
10.1093/eurheartj/ehp187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle tracking algorithm was recently developed. Our goal was to evaluate the accuracy of the new 3D-STE side by side with 2D-STE using cardiac magnetic resonance (CMR) as a reference. Apical two- and four-chamber views (A2C and A4C) and real-time 3D datasets (Toshiba Artida 4D System) obtained in 43 patients with a wide range of LV size and function were analysed to measure LV end-systolic and end-diastolic volumes (ESV and EDV) using 2D and 3D-STE techniques. Short-axis CMR images (Siemens 1.5T scanner) acquired on the same day were analysed to obtain ESV and EDV reference values using the method of disks approximation. Reproducibility of both STE techniques was assessed using repeated measurements. While 2D-STE correlated well with CMR (r: 0.72-0.88), it underestimated LV volumes with relatively large biases (10-30 mL) and wide limits of agreement (SD: 36-51 mL), with A2C-derived measurements being worse than A4C values. The 3D-STE measurements showed higher correlation with CMR (0.87-0.92), and importantly smaller biases (1-16 mL) and narrower limits of agreement (SD: 28-37 mL). In addition, 3D-STE showed lower inter- and intra-observer variability (11-14% and 12-13%), than 2D-STE (16-17% and 12-16%, respectively). This is the first study to validate the new 3D-STE technique for LV volume measurements and demonstrate its superior accuracy and reproducibility over previously used 2D-STE technique.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 43 条
  • [1] Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging
    Amundsen, BH
    Helle-Valle, T
    Edvardsen, T
    Torp, H
    Crosby, J
    Lyseggen, E
    Stoylen, A
    Ihlen, H
    Lima, JAC
    Smiseth, OA
    Slordahl, SA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 789 - 793
  • [2] Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging
    Amundsen, Brage H.
    Crosby, Jonas
    Steen, Per Arvid
    Torp, Hans
    Slordahl, Stig A.
    Stoylen, Asbjorn
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02): : 229 - 237
  • [3] Speckle-tracking strain echocardiography for detecting cardiac dyssynchrony in a canine model of dyssynchrony and heart failure
    Arita, Takeshi
    Sorescu, George P.
    Schuler, Brian T.
    Schmarkey, Laura S.
    Merlino, John D.
    Vinten-Johansen, Jakob
    Leon, Angel R.
    Martin, Randolph P.
    Sorescu, Dan
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 293 (01): : H735 - H742
  • [4] Burns AT, 2008, EUR HEART J, V29, P825, DOI 10.1093/eurheartj/ehn004
  • [5] 3-D correlation-based speckle tracking
    Chen, X
    Xie, H
    Erkamp, R
    Kim, K
    Jia, C
    Rubin, JM
    O'Donnell, M
    [J]. ULTRASONIC IMAGING, 2005, 27 (01) : 21 - 36
  • [6] Effect of preload on left ventricular longitudinal strain by 2D speckle tracking
    Choi, Jin-Oh
    Shin, Dae-Hee
    Cho, Sung Won
    Bin Song, Young
    Kim, Jun Hyung
    Kim, Yoon Goo
    Lee, Sang-Chol
    Park, Seung Woo
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (08): : 873 - 879
  • [7] Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images
    Corsi, C
    Lang, RM
    Veronesi, F
    Weinert, L
    Caiani, EG
    MacEneaney, P
    Lamberti, C
    Mor-Avi, V
    [J]. CIRCULATION, 2005, 112 (08) : 1161 - 1170
  • [8] Assessment of left ventricular dyssynchrony by speckle tracking strain imaging - Comparison between longitudinal, circumferential, and radial strain in cardiac resynchronization therapy
    Delgado, Victoria
    Ypenburg, Claudia
    van Bommel, Rutger J.
    Tops, Laurens F.
    Mollema, Sjoerd A.
    Marsan, Nina Ajmone
    Bleeker, Gabe B.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (20) : 1944 - 1952
  • [9] Assessment of longitudinal and radial ventricular dyssynchrony in ischemic and nonischemic chronic Systolic heart failure: A two-dimensional echocardiographic speckle-tracking strain study
    Donal, Erwan
    Tournoux, Francois
    Leclercq, Christophe
    De Place, Christian
    Solnon, Aude
    Derumeaux, Genevive
    Mabo, Philippe
    Cohen-Solal, Alain
    Daubert, Jean-Claude
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (01) : 58 - 65
  • [10] Relation between left ventricular regional radial function and radial wall motion abnormalities using two-dimensional speckle tracking in children with idiopathic dilated cardiomyopathy
    Friedberg, Mark Kevin
    Slorach, Cameron
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (03) : 335 - 339