Flow cytometric determination of residual white blood cell levels in preserved samples from leukoreduced blood products

被引:17
作者
Palmer, Douglas S. [1 ]
Birch, Paul [1 ]
O'Toole, Joan [1 ]
Henderson, Deborah [1 ]
Scalia, Vito [1 ]
机构
[1] Canadian Blood Serv, Natl Testing Lab, Ottawa, ON K1G 4J5, Canada
关键词
D O I
10.1111/j.1537-2995.2007.01489.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
BACKGROUND: In preparation for a proposed consolidated testing service, Canadian Blood Services undertook the evaluation of a commercial test kit for the enumeration by flow cytometry of residual white blood cells (rWBCs) present in preserved samples recovered from leukoreduced (LR) blood and platelet products. STUDY DESIGN AND METHODS: The stability of preserved WBCs, the equivalency of WBCs used for spiking, test method precision, specificity, reliability, accuracy, and sensitivity were investigated. For comparative purposes, WBC counts were also determined by Nageotte as well as by flow cytometry. RESULTS: WBCs were stable up to 4 weeks at room temperature for all components by either method. Within methods, no differences were observed due to the source of WBC used for spiking purposes. By either method, test precision was acceptable (< 20% coefficient of variation) and of similar reliability at a target value of 10 +/- 5 WBCs per mu L. The flow cytometric method was shown to be more specific and accurate than the Nageotte method. Sensitivity by either method was 0.1 WBCs per mu L. On average, Nageotte counts were lower than those observed by flow cytometry. CONCLUSIONS: These results demonstrate that WBCs in WBC stabilizing solution-treated samples from LR blood components were stabilized up to 4 weeks at room temperature and that rWBC determinations made with a WBC enumeration kit by flow cytometry have the required precision, specificity, reliability, and accuracy in the relevant test range. This validated WBC stabilization and flow cytometric counting method is considered acceptable as part of a quality control program for leukoreduced blood products.
引用
收藏
页码:118 / 128
页数:11
相关论文
共 38 条
[1]
A rapid and reliable flow cytometric routine method for counting leucocytes in leucocyte-depleted platelet concentrates [J].
Backteman, K ;
Ledent, E ;
Berlin, G ;
Ernerudh, J .
VOX SANGUINIS, 2002, 83 (01) :29-34
[2]
Barclay GR, 2000, TRANSFUSION MED, V10, P37
[3]
Flow cytometric determination of residual leucocytes in filter-depleted blood products: An evaluation of Becton-Dickinson's LeucoCOUNT systems [J].
Barclay, R ;
Walker, B ;
Allan, R ;
Reid, C ;
Duffin, E ;
Kane, E ;
Turner, M .
TRANSFUSION SCIENCE, 1998, 19 (04) :399-403
[4]
The origin and identification of unknown events associated with low-level leucocyte counting by flow cytometry [J].
Bashir, S ;
Cardigan, R .
VOX SANGUINIS, 2003, 85 (03) :190-198
[5]
A FLOW CYTOMETRIC TECHNIQUE TO ACCURATELY MEASURE POST-FILTRATION WHITE BLOOD-CELL COUNTS [J].
BODENSTEINER, DC .
TRANSFUSION, 1989, 29 (07) :651-653
[6]
Apoptosis in leucodepleted packed red blood cells [J].
Bontadini, A ;
Tazzari, PL ;
Manfroi, S ;
Tassi, C ;
Conte, R .
VOX SANGUINIS, 2002, 83 (01) :35-41
[7]
Evaluation of leukocyte stabilisation in TransFix®-treated blood samples by flow cytometry and transmission electron microscopy [J].
Canonico, B ;
Zamai, L ;
Burattini, S ;
Granger, V ;
Mannello, F ;
Gobbi, P ;
Felici, C ;
Falcieri, E ;
Reilly, JT ;
Barnett, D ;
Papa, S .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 295 (1-2) :67-78
[8]
Process control of filtered red blood cells: which counting method? [J].
Conte, R ;
Bontadini, A ;
Cirillo, D ;
Fruet, F .
TRANSFUSION MEDICINE, 1997, 7 (03) :217-219
[9]
White blood cell fragments in platelet concentrates prepared by the platelet-rich plasma or buffy-coat methods [J].
Dijkstra-Tiekstra, MJ ;
van der Schoot, CE ;
Pietersz, RNI ;
Reesink, HW .
VOX SANGUINIS, 2005, 88 (04) :275-277
[10]
Development of white blood cell fragments, during the preparation and storage of platelet concentrates, as measured by using real-time polymerase chain reaction [J].
Dijkstra-Tiekstra, MJ ;
van der Schoot, CE ;
Pietersz, RNI ;
Huijgens, PC ;
van der Meer, PF ;
Reesink, HW .
VOX SANGUINIS, 2004, 87 (04) :250-256