Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE)

被引:75
作者
Emenius, G
Svartengren, M
Korsgaard, J
Nordvall, L
Pershagen, G
Wickman, M
机构
[1] Stockholm Cty Council, Dept Environm Hlth, SE-17176 Stockholm, Sweden
[2] Karolinska Inst, Inst Environm Med, SE-17177 Stockholm, Sweden
[3] Karolinska Inst Norrbacks, Inst Publ Hlth Sci, SE-17176 Stockholm, Sweden
[4] Cent Sygehuset, DK-8600 Silkeborg, Denmark
[5] Uppsala Univ, Dept Womens & Childrens Hlth, SE-75185 Uppsala, Sweden
关键词
building; wheezing; asthma; air quality; indoor environment;
D O I
10.1046/j.1600-0668.2003.00207.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study was conducted to examine the impact of building characteristics and indoor air quality on recurrent wheezing in infants. We followed a birth cohort (BAMSE) comprising 4089 children, born in predefined areas of Stockholm, during their first 2 years of life. Information on exposures was obtained from parental questionnaires when the children were 2 months and on symptoms and diseases when the children were 1 and 2 years old. Children with recurrent wheezing, and two age-matched controls per case, were identified and enrolled in a nested case-control study. The homes were investigated and ventilation rate, humidity, temperature and NO2 measured. We found that living in an apartment erected after 1939, or in a private home with crawl space/concrete slab foundation were associated with an increased risk of recurrent wheezing, odds ratio (OR) 2.5 (1.3-4.8) and 2.5 (1.1-5.4), respectively. The same was true for living in homes with absolute indoor humidity >5.8 g/kg, OR 1.7 (1.0-2.9) and in homes where windowpane condensation was consistently reported over several years, OR 2.2 (1.1-4.5). However, air change rate and type of ventilation system did not seem to affect the risk. In conclusion, relatively new apartment buildings, single-family homes with crawl space/concrete slab foundation, elevated indoor humidity, and reported wintertime windowpane condensation were associated with recurrent wheezing in infants. Thus, improvements of the building quality may have potential to prevent infant wheezing.
引用
收藏
页码:34 / 42
页数:9
相关论文
共 42 条
[21]   Residential exposures associated with asthma in US children [J].
Lanphear, BP ;
Aligne, CA ;
Auinger, P ;
Weitzman, M ;
Byrd, RS .
PEDIATRICS, 2001, 107 (03) :505-511
[22]  
LEE T, 2002, P IND AIR 2002, V2, P742
[23]   Ventilation and radon transport in Dutch dwellings: computer modelling and field measurements [J].
Lembrechts, J ;
Janssen, M ;
Stoop, P .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 272 (1-3) :73-78
[24]   INDOOR ENVIRONMENTAL RISK-FACTORS IN YOUNG ASTHMATICS - A CASE-CONTROL STUDY [J].
LINDFORS, A ;
WICKMAN, M ;
HEDLIN, G ;
PERSHAGEN, G ;
RIETZ, H ;
NORDVALL, SL .
ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (05) :408-412
[25]  
Luczynska C, 1998, CLIN EXP ALLERGY, V28, P1201, DOI 10.1046/j.1365-2222.1998.00410.x
[26]   A 2-SITE MONOCLONAL-ANTIBODY ELISA FOR THE QUANTIFICATION OF THE MAJOR DERMATOPHAGOIDES SPP ALLERGENS, DER P-I AND DER F-I [J].
LUCZYNSKA, CM ;
ARRUDA, LK ;
PLATTSMILLS, TAE ;
MILLER, JD ;
LOPEZ, M ;
CHAPMAN, MD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 118 (02) :227-235
[27]  
MATILAINEN M, 2002, P IND AIR 2002, V2, P736
[28]  
NORBERG P, 1993, INDOOR AIR, V3, P398
[29]  
NORLEN U, 1993, D10 SWED COUNC BUILD
[30]   The ventilation rate of 344 Oslo residences [J].
Oie, L ;
Stymne, H ;
Boman, CA ;
Hellstrand, V .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (03) :190-196