Two New "Protected" Oxyphors for Biological Oximetry: Properties and Application in Tumor Imaging

被引:197
作者
Esipova, Tatiana V. [1 ]
Karagodov, Alexander [1 ]
Miller, Joann [2 ]
Wilson, David F. [1 ]
Busch, Theresa M. [2 ]
Vinogradov, Sergei A. [1 ]
机构
[1] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
OXYGEN SENSORS; PHOSPHORESCENT PROBES; OPTICAL-PROPERTIES; MOLECULAR-OXYGEN; PARTIAL-PRESSURE; LIVING CELLS; BLOOD-FLOW; LUMINESCENCE; FLUORESCENCE; COMPLEXES;
D O I
10.1021/ac2022234
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the synthesis, calibration, and examples of application of two new phosphorescent probes, Oxyphor R4 and Oxyphor G4, optimized specifically for in vivo oxygen imaging by phosphorescence quenching. These "protected" dendritic probes can operate in either albumin-rich (blood plasma) or albumin-free (interstitial space) environments at all physiological oxygen concentrations, from norroxic to deep hypoxic conditions. Oxyphors R4 and G4 are derived from phosphorescent Pd-meso-tetra-(3,5-dicarboxyphenyl)-porphyrin. (PdP) or Pd-meso-tetra-(3,5-dicarboxyphenyl)-tetrabenzoporphyrin (PdTBP), respectively, and possess features common for protected dendritic probes, i.e., hydrophobic dendritic encapsulation of phosphorescent metalloporphyrins and hydrophilic PEGylated periphery. The new Oxyphors are highly soluble in aqueous environments and do not permeate biological membranes. The probes were calibrated under physiological conditions (pH 6.4-7.8) and temperatures (22-38 degrees C), showing high stability, reproducibility of signals, and lack of interactions with biological solutes. Oxyphor G4 was used to dynamically image intravascular and interstitial oxygenation in murine tumors in vivo. The physiological relevance of the measurements was demonstrated by dynamically recording changes in tissue oxygenation during application of anesthesia (isofluorane). These experiments revealed that changes in isofluorane concentration significantly affect tissue oxygenation.
引用
收藏
页码:8756 / 8765
页数:10
相关论文
共 85 条
[1]   Tomographic imaging of oxygen by phosphorescence lifetime [J].
Apreleva, Sovia V. ;
Wilson, David F. ;
Vinogradov, Sergei A. .
APPLIED OPTICS, 2006, 45 (33) :8547-8559
[2]   Sol gel-immobilised terbium complexes for luminescent sensing of dissolved oxygen by analysis of emission decay [J].
Blair, S ;
Kataky, R ;
Parker, D .
NEW JOURNAL OF CHEMISTRY, 2002, 26 (05) :530-535
[3]   Free radicals, mitochondria, and hypoxia-ischemia in the developing brain [J].
Blomgren, K ;
Hagberg, H .
FREE RADICAL BIOLOGY AND MEDICINE, 2006, 40 (03) :388-397
[4]   Photophysical properties of the new phosphorescent platinum(II) and palladium(II) complexes of benzoporphyrins and chlorins [J].
Borisov, S. M. ;
Papkovsky, D. B. ;
Ponomarev, G. V. ;
DeToma, A. S. ;
Saf, R. ;
Klimant, I. .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2009, 206 (01) :87-92
[5]   Ultrabright oxygen optodes based on cyclometalated lridium(III) coumarin complexes [J].
Borisov, Sergey M. ;
Klimant, Ingo .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7501-7509
[6]   Luminescent nanobeads for optical sensing and imaging of dissolved oxygen [J].
Borisov, Sergey M. ;
Klimant, Ingo .
MICROCHIMICA ACTA, 2009, 164 (1-2) :7-15
[7]   Phosphorescent oxygen sensor with dendritic protection and two-photon absorbing antenna [J].
Briñas, RP ;
Troxler, T ;
Hochstrasser, RM ;
Vinogradov, SA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (33) :11851-11862
[8]   Dipyrrin based luminescent cyclometallated palladium and platinum complexes [J].
Bronner, Catherine ;
Baudron, Stephane A. ;
Hosseini, Mir Wais ;
Strassert, Cristian A. ;
Guenet, Aurelie ;
De Cola, Luisa .
DALTON TRANSACTIONS, 2010, 39 (01) :180-184
[9]   TUMOR HYPOXIA, DRUG-RESISTANCE, AND METASTASES [J].
BROWN, JM .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1990, 82 (05) :338-339
[10]  
Castellano FN, 1998, PHOTOCHEM PHOTOBIOL, V67, P179, DOI 10.1562/0031-8655(1998)067<0179:AWSLOS>2.3.CO