Digital thoracic radiography using a selenium detector: Prospective comparison with conventional radiography

被引:7
作者
Freund, M [1 ]
Reuter, M [1 ]
Palmie, S [1 ]
Harder, E [1 ]
Hutzelmann, A [1 ]
Heller, M [1 ]
机构
[1] CHRISTIAN ALBRECHTS UNIV KIEL, RADIOL DIAGNOST KLIN, KIEL, GERMANY
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 166卷 / 02期
关键词
digital thoracic radiography; detector; conventional radiography; lung; radiation dose;
D O I
10.1055/s-2007-1015390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare a new digital chest radiography system that uses amorphous selenium as the x-ray detector, with conventional radiography for the detection of pathological alterations of the chest. Material and methods: Two observers analysed pairs of posteroanterior and lateral chest radiographs of 95 patients. One pair of radiographs was obtained with the digital selenium chest radiography system, and the other with conventional film-screen technique. 9 criteria were rated using a 4 point scale. Technical parameters were standardised. Radiation dose was measured in both techniques and compared. Results: A-total of 855 criteria were rated. 740 findings were diagnosed in accordance on both techniques ((740)/(855) = 87 %). 115 criteria ((115)/(855) = 13%) showed deviations. The mean radiation dose for the selenium detector was 0.02 cGy and for the conventional system 0.11 cGy. Conclusion: The exposure of radiation is lower using a selenium x-ray detector compared to conventional film-screen technique in chest radiography. The digital selenium system performs well in a clinical setting, providing visualisation of pathotogical findings as good as a standard screen-film system.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 23 条
[1]   CHEST RADIOGRAPHS WITH THE AMBER SYSTEM [J].
BUSCH, HP ;
HARTMANN, J ;
FREUND, MC ;
LEHMANN, KJ ;
GEORGI, M ;
RICHTER, K .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (03) :241-246
[2]  
BUSCH HP, 1992, EUR RADIOL, V2, P335
[3]   TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR [J].
CHOTAS, HG ;
FLOYD, CE ;
RAVIN, CE .
RADIOLOGY, 1995, 195 (01) :264-270
[4]   FILM-BASED CHEST RADIOGRAPHY - AMBER VS ASYMMETRIC SCREEN-FILM SYSTEMS [J].
CHOTAS, HG ;
FLOYD, CE ;
RAVIN, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) :743-747
[5]   DIGITAL CHEST RADIOGRAPHY - COMPARISON OF UNPROCESSED AND PROCESSED IMAGES IN THE DETECTION OF SOLITARY PULMONARY NODULES [J].
CORREA, J ;
SOUTO, M ;
TAHOCES, PG ;
MALAGARI, KS ;
TUCKER, DM ;
LARKIN, JJ ;
KUHLMAN, J ;
BARNES, GT ;
ZERHOUNI, EA ;
FRASER, RG ;
VIDAL, JJ .
RADIOLOGY, 1995, 195 (01) :253-258
[6]   INTERSTITIAL PULMONARY-DISEASE - A COMPARISON BETWEEN FILM-SCREEN TECHNIQUE AND DIGITAL STORAGE PHOSPHOR TECHNIQUE [J].
DOLKEN, W ;
CHOWANETZ, W ;
HORWITZ, AE ;
KRAHE, T ;
LANDWEHR, P ;
LACKNER, K .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01) :61-67
[7]   VALUE OF THE ASYMMETRIC FILM-SCREEN SYSTEM INSIGHT HC IN CHEST IMAGING [J].
HAUSSLER, MD ;
LENZEN, H ;
RECKELS, C ;
PETERS, PE .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (03) :266-270
[8]   DIGITAL CHEST IMAGING WITH A SELENIUM DETECTOR - COMPARISON WITH CONVENTIONAL RADIOGRAPHY FOR VISUALIZATION OF SPECIFIC ANATOMIC REGIONS OF THE CHEST [J].
HEESEWIJK, HPM ;
NEITZEL, U ;
VANDERGRAAF, Y ;
DEVALOIS, JC ;
FELDBERG, MAM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :535-540
[9]   ROC ANALYSIS FOR POST-PROCESSING OF IMAGE DATA OF DIGITAL LUMINESCENCE RADIOGRAPHS OF THE THORAX [J].
MULLER, RD ;
HIRCHE, H ;
VOSS, M ;
BUDDENBROCK, B ;
JOHN, V ;
GOCKE, P .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (02) :163-169
[10]   IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR [J].
NEITZEL, U ;
MAACK, I ;
GUNTHERKOHFAHL, S .
MEDICAL PHYSICS, 1994, 21 (04) :509-516