DNA hybridization biosensors using polylysine modified SPCEs

被引:33
作者
Diaz-Gonzalez, Maria [1 ]
de la Escosura-Muniz, Alfredo [1 ]
Gonzalez-Garcia, Maria Begona [1 ]
Costa-Garcia, Agustin [1 ]
机构
[1] Univ Oviedo, Fac Quim, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
关键词
genosensor; polylysine; alkaline phosphatase; sodium aurothiomalate; screen-printed carbon electrode; SARS virus;
D O I
10.1016/j.bios.2007.12.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Two electrochemical DNA hybridization biosensors (genosensors) for the detection of a 30-mer sequence unique to severe acute respiratory syndrome (SARS) virus are described in this work. Both genosensors rely on the hybridization of the oligonucleotide target with its complementary probe, which is immobilized on positively charged polylysine modified screen-printed carbon electrodes (SPCEs), through electrostatic interactions. In one design, a biotinylated target is used and the detection of the hybridization reaction is monitored using alkaline phosphatase labeled streptavidin (S-AP). This enzyme catalyzes the hydrolysis of the substrate 3-indoxyl phosphate (3-IP) to indigo, which is then solubilized to indigo carmine and detected by means of cyclic voltammetry (CV). In the other design, the target is labeled using an Au(I) complex, sodium aurothiomalate, and the duplex formation is detected by measuring, for first time, the current generated by the hydrogen evolution catalyzed by the gold label. Using 30 min of hybridization time, a detection limit of 8 pM is calculated for the enzymatic genosensor. Although this good sensitivity cannot be reached with the metal label (0.5 nM), the use of this label allows a considerable decrease of the analysis time. Both genosensors do not require the modification of the oligonucleotide probe and using stringent experimental conditions (60 min of hybridization time and 50% formamide in the hybridization buffer) can discriminate between a complementary oligonucleotide and an oligonucleotide with a three-base mismatch. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1340 / 1346
页数:7
相关论文
共 37 条
[1]   Genosensor on gold films with enzymatic electrochemical detection of a SARS virus sequence [J].
Abad-Valle, P ;
Fernandez-Abedul, MT ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2251-2260
[2]   Amperometric DNA biosensor for the determination of auto-antibodies using DNA interaction with Pt(II) complex [J].
Babkina, SS ;
Ulakhovich, NA ;
Zyavkina, YI .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :23-30
[3]   Application of spectral analysis to examine phylogenetic signal among euglenid SSU rDNA data sets (Euglenozoa) [J].
Busse, I ;
Preisfeld, A .
ORGANISMS DIVERSITY & EVOLUTION, 2003, 3 (01) :1-12
[4]   Cu@Au alloy nanoparticle as oligonucleotides labels for electrochemical stripping detection of DNA hybridization [J].
Cai, H ;
Zhu, NN ;
Jiang, Y ;
He, PG ;
Fang, YZ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (11) :1311-1319
[5]   Aurothiomalate as an electroactive label for the determination of immunoglobulin M using glassy carbon electrodes as immunoassay transducers [J].
de la Escosura-Muñiz, A ;
González-García, MBE ;
Costa-García, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :473-481
[6]   Determination of human serum albumin using aurothiomalate as electroactive label [J].
de la Escosura-Muñiz, A ;
González-García, MB ;
Costa-García, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (03) :742-750
[7]   Electrocatalytic detection of aurothiomalate on carbon electrodes -: Application as a non-enzymatic label to the quantification of proteins [J].
de la Escosura-Muñiz, A ;
González-García, MB ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) :355-363
[8]   Catalytic effect on silver electrodeposition of gold deposited on carbon electrodes [J].
de la Escosura-Muñiz, A ;
González-García, MB ;
Costa-García, A .
ELECTROANALYSIS, 2004, 16 (19) :1561-1568
[9]   DNA hybridization sensor based on aurothiornalate electroactive label on glassy carbon electrodes [J].
de la Escosura-Muniz, Alfredo ;
Gonzalez-Garcia, Maria Begona ;
Costa-Garcia, Agustin .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :1048-1054
[10]   Voltammetric determination of underivatized oligonucleotides on graphite electrodes based on their oxidation products [J].
de-Los-Santos-Alvarez, P ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3342-3347