Continued axillary sampling is unnecessary and provides no further information to sentinel node biopsy in staging breast cancer

被引:17
作者
Gui, GPH
Joubert, DJ
Reichert, R
Ward, A
Lakhani, S
Osin, P
Nerurkar, A
A'Hern, R
Benson, K
Underwood, SR
机构
[1] Royal Marsden NHS Fdn Trust, Acad Surg & Breast Unit, London SW3 6JJ, England
[2] Royal Marsden NHS Fdn Trust, Dept Pathol Anat, London SW3 6JJ, England
[3] Royal Marsden NHS Fdn Trust, Breakthrough Toby Robins Breast Canc Res Ctr, London SW3 6JJ, England
[4] Royal Marsden NHS Fdn Trust, Dept Informat Technol & Stat, London SW3 6JJ, England
[5] Royal Brompton Hosp, Dept Nucl Med, London SW3 6LY, England
来源
EJSO | 2005年 / 31卷 / 07期
关键词
sentinel lymph node biopsy; axillary dissection; axillary sample; sensitivity;
D O I
10.1016/j.ejso.2005.04.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Sentinel lymph node biopsy (SLNB) has become increasingly accepted as a diagnostic method to stage the axilla in breast cancer, selecting women with a positive sentinel node for completion axillary clearance. As SLNB became established, many surgeons supplemented SLNB to sample a minimum of four lymph nodes, on the assumption that the four-node technique is supported by randomised trial data. We hypothesised that the practice of undirected sampling to supplement SLNB adds little information to the status of the residual axilla. Methods: One hundred and sixty-five patients with early breast cancer were studied. Following successful identification of the sentinel node, 84 women had completion axillary dissection and 81 women had an axillary sample with at least four nodes available for pathological assessment. Results: Following successful identification of the sentinel node in 165 patients, the false negative rate (FNR) was 2/44=4.5% (95% Cl 0.6-15.5), sensitivity 42/44=95.5% (84.5-99.4) and negative predictive value (NPV) 121/123 = 98.4% (94.2-99.8). In the axillary dissection cohort, the FNR was 2/26=7.7% (0.9-25.1), sensitivity 24/26= 92.3% (74.9-99.1) and NPV 58/60=96.7% (88.5-100). In the axillary sample group, the FNR was 0/18 = 0% (0-18.5), sensitivity 18/18 = 100% (81.5-100) and NPV 63/63=100% (94.3-100). The SLNB was the only positive node in 12/26 (46.2%) in the axillary dissection group and 10/18 (55.6%) in the axillary sampling group. There was no patient in the axillary sampling group where the sample node was positive and the sentinel node negative. Conclusion: Once SLNB is validated within the multidisciplinary unit, undirected sampling of the axilla following identification of the sentinel node(s) is unnecessary. The additional sampling of non-sentinel nodes has no rote to play either in the assessment of a potential false negative SLNB nor as predictive information on the status of the residual axillary nodes. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 31 条
[21]   RISK OF LYMPHEDEMA FOLLOWING THE TREATMENT OF BREAST-CANCER [J].
KISSIN, MW ;
DELLAROVERE, GQ ;
EASTON, D ;
WESTBURY, G .
BRITISH JOURNAL OF SURGERY, 1986, 73 (07) :580-584
[22]   The sentinel node in breast cancer - A multicenter validation study [J].
Krag, D ;
Weaver, D ;
Ashikaga, T ;
Moffat, F ;
Klimberg, VS ;
Shriver, C ;
Feldman, S ;
Kusminsky, R ;
Gadd, M ;
Kuhn, J ;
Harlow, S ;
Beitsch, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (14) :941-946
[23]   NSABP-32: Phase III, randomized trial comparing axillary resection with sentinal lymph node dissection: A description of the trial [J].
Krag, DN ;
Julian, TB ;
Harlow, SP ;
Weaver, DL ;
Ashikaga, T ;
Bryant, J ;
Single, RM ;
Wolmark, N .
ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (03) :208S-210S
[24]   Sentinel node biopsy for breast cancer may have little to offer four-node-samplers: results of a prospective comparison study [J].
Macmillan, RD ;
Barbera, D ;
Hadjiminas, DJ ;
Rampaul, RS ;
Lee, AHS ;
Pinder, SE ;
Ellis, IO ;
Blamey, RW ;
Geraghty, JG .
EUROPEAN JOURNAL OF CANCER, 2001, 37 (09) :1076-1080
[25]  
McIntosh SA, 1998, BRIT J SURG, V85, P1347
[26]   The implementation of the sentinel node biopsy as a routine procedure for patients with breast cancer [J].
Rahusen, FD ;
Pijpers, R ;
van Diest, PJ ;
Bleichrodt, RP ;
Torrenga, H ;
Meijer, S .
SURGERY, 2000, 128 (01) :6-12
[27]   Management of the axilla in breast cancer: a comparative study between sentinel lymph node biopsy and four-node sampling procedure [J].
Sato, K ;
Tamaki, K ;
Takeuchi, H ;
Tsuda, H ;
Kosuda, S ;
Kusano, S ;
Hiraide, H ;
Mochizuki, H .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2001, 31 (07) :318-321
[28]  
SCHWARTZ F, 2002, HUM PATHOL, V33, P579
[29]   Final results of the department of defense multicenter breast lymphatic mapping trial [J].
Shivers, S ;
Cox, C ;
Leight, G ;
Beauchamp, D ;
Blumencranz, P ;
Ross, M ;
Reintgen, D .
ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (03) :248-255
[30]   False negative sentinel node procedure established through palpation of the biopsy wound [J].
Tanis, PJ ;
Nieweg, OE ;
Merkus, JWS ;
Peterse, JL ;
Kroon, BBR .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2000, 26 (07) :714-715