How should airways resistance be measured in young children: mask or mouthpiece?

被引:19
作者
Child, F
Clayton, S
Davies, S
Fryer, AA
Jones, PW
Lenney, W
机构
[1] City Gen Hosp, Acad Dept Paediat, N Staffordshire Royal Infirm, Stoke On Trent ST4 6QG, Staffs, England
[2] Univ Keele, Ctr Cell & Mol Med, N Staffordshire Royal Infirm, Stoke On Trent, Staffs, England
[3] Univ Keele, Dept Math, Keele ST5 5BG, Staffs, England
关键词
airway resistance child; interrupter technique; masks; reproducibility of results; respiratory function tests;
D O I
10.1183/09031936.01.00089501
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The reproducibility and acceptability of airways resistance measurements using the interrupter technique (MicroRint) obtained using a mouthpiece were compared with those using a face mask. Fifty children aged 4-7 yrs performed four sets of six Rint measurements; tno using a mouthpiece and two using a face mask with integral mouthpiece. Complete data were obtained from 45 (90%) children using the mouthpiece and 43 (86%) children using the mask. The tno methods were equally repeatable with comparable intraclass correlation coefficients (ICC) and coefficients of variation. Mean Rint values obtained using the mouthpiece were significantly lo,rer than those using the face mask ((mean +/- SD) mouthpiece = 0.81 +/-0.18 kPa.L-1.s, mask = 0.88 +/-0.24 kPa.L-1.s p = 0.0002), Although the mean paired differences between the tno methods were small (0.07 kPa.L-1.s), the ICC and limits of agreement confirmed that the two methods could not be used interchangeably. Sixty-seven per cent of children preferred the face mask but this was more time-consuming (p = 0.03), Children did not produce more repeatable results using their preferred method, nor did they improve with practice. Repeatable airway resistance measurements using the interrupter technique ran be obtained from young children using either a mouthpiece or a face mask, but there are significant clinical and statistical differences between the results obtained.
引用
收藏
页码:1244 / 1249
页数:6
相关论文
共 31 条
[1]   EFFECTS OF RESPIRATORY APPARATUS ON BREATHING PATTERN [J].
ASKANAZI, J ;
SILVERBERG, PA ;
FOSTER, RJ ;
HYMAN, AI ;
MILICEMILI, J ;
KINNEY, JM .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 48 (04) :577-580
[2]   Lung function measurement in awake young children [J].
Bisgaard, H ;
Klug, B .
EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (12) :2067-2075
[3]   A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren [J].
Bridge, PD ;
Lee, H ;
Silverman, M .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (07) :1368-1373
[4]   Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting [J].
Bridge, PD ;
Ranganathan, S ;
McKenzie, SA .
EUROPEAN RESPIRATORY JOURNAL, 1999, 13 (04) :792-796
[5]   EVALUATION OF THE INTERRUPTER TECHNIQUE FOR THE USE OF ASSESSING AIRWAY-OBSTRUCTION IN CHILDREN [J].
CARTER, ER ;
STECENKO, AA ;
POLLOCK, BH ;
JAEGER, MJ .
PEDIATRIC PULMONOLOGY, 1994, 17 (04) :211-217
[6]  
CHOWIENCZYK PJ, 1991, EUR RESPIR J, V4, P623
[7]  
Dunn G., 1989, Design and analysis of reliability studies: the statistical evaluation of measurement errors
[8]   Oscillatory pressure transients after flow interruption during bronchial challenge test in children [J].
Frey, U ;
Kraemer, R .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (01) :75-81
[9]  
Kannisto S, 1999, PEDIATR PULM, V27, P203, DOI 10.1002/(SICI)1099-0496(199903)27:3<203::AID-PPUL9>3.0.CO
[10]  
2-G