Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential

被引:199
作者
Winklehner, Anna [1 ]
Karlo, Christoph [1 ]
Puippe, Gilbert [1 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Goetti, Robert [1 ]
Pfammatter, Thomas [1 ]
Frauenfelder, Thomas [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Healthcare, Forchheim, Germany
关键词
Computed tomography; Angiography; Iterative reconstruction; Raw data; Radiation dose; Image quality; REDUCTION; ANGIOGRAPHY;
D O I
10.1007/s00330-011-2227-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To evaluate prospectively, in patients undergoing body CTA, the radiation dose saving potential of raw data-based iterative reconstruction as compared to filtered back projection (FBP). Twenty-five patients underwent thoraco-abdominal CTA with 128-slice dual-source CT, operating both tubes at 120 kV. Full-dose (FD) images were reconstructed with FBP and were compared to half-dose (HD) images with FBP and HD-images with sinogram-affirmed iterative reconstruction (SAFIRE), both reconstructed using data from only one tube-detector-system. Image quality and sharpness of the aortic contour were assessed. Vessel attenuation and noise were measured, contrast-to-noise-ratio was calculated. Noise as image quality deteriorating artefact occurred in 24/25 (96%) HD-FBP but not in FD-FBP and HD-raw data-based iterative reconstruction datasets (p < 0.001). Other artefacts occurred with similar prevalence among the datasets. Sharpness of the aortic contour was higher for FD-FBP and HD-raw data-based iterative reconstruction as compared to HD-FBP (p < 0.001). Aortoiliac attenuation was similar among all datasets (p > 0.05). Lowest noise was found for HD-raw data-based iterative reconstruction (7.23HU), being 9.4% lower than that in FD-FBP (7.98HU, p < 0.05) and 30.8% lower than in HD-FBP images (10.44HU, p < 0.001). Contrast-to-noise-ratio was lower in HD-FBP (p < 0.001) and higher in HD-raw data-based iterative reconstruction (p < 0.001) as compared to FD-FBP. Intra-individual comparisons of image quality of body CTA suggest that raw data-based iterative reconstruction allows for dose reduction > 50% while maintaining image quality. Key Points aEuro cent Raw data-based iterative reconstruction reduces image noise and improves image quality as compared to filtered back projection aEuro cent At a similar radiation dose, raw data-based iterative reconstruction improves the sharpness of vessel contours aEuro cent In body CTA a dose reduction of > 50% might be possible when using raw data-based iterative reconstructions, while image quality can be maintained.
引用
收藏
页码:2521 / 2526
页数:6
相关论文
共 13 条
[1]
AAPM, 2008, MEASUREMENT REPORTIN
[2]
State of the art low-dose CT angiography of the body [J].
Alkadhi, Hatem ;
Schindera, Sebastian T. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) :36-40
[3]
Barrett H.H., 1981, RADIOLOGICAL IMAGING
[4]
Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[5]
Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? [J].
Macari, Michael ;
Chandarana, Hersh ;
Schmidt, Bernhardt ;
Lee, Julie ;
Lamparello, Patrick ;
Babb, James .
RADIOLOGY, 2006, 241 (03) :908-914
[6]
Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography [J].
May, Matthias S. ;
Wuest, Wolfgang ;
Brand, Michael ;
Stahl, Christian ;
Allmendinger, Thomas ;
Schmidt, Bernhard ;
Uder, Michael ;
Lell, Michael M. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (07) :465-470
[7]
CT dose reduction and dose management tools: Overview of available options [J].
McCollough, Cynthia H. ;
Bruesewitz, Michael R. ;
Kofler, James M., Jr. .
RADIOGRAPHICS, 2006, 26 (02) :503-U14
[8]
Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients [J].
Pontana, Francois ;
Pagniez, Julien ;
Flohr, Thomas ;
Faivre, Jean-Baptiste ;
Duhamel, Alain ;
Remy, Jacques ;
Remy-Jardin, Martine .
EUROPEAN RADIOLOGY, 2011, 21 (03) :627-635
[9]
Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients [J].
Pontana, Francois ;
Duhamel, Alain ;
Pagniez, Julien ;
Flohr, Thomas ;
Faivre, Jean-Baptiste ;
Hachulla, Anne-Lise ;
Remy, Jacques ;
Remy-Jardin, Martine .
EUROPEAN RADIOLOGY, 2011, 21 (03) :636-643
[10]
Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Kambadakone, Avinash K. ;
Pien, Homer ;
Hsieh, Jiang ;
Blake, Michael A. ;
Sahani, Dushyant V. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (04) :202-210