Experimental determination of dosimetry functions of Ir-192 sources

被引:33
作者
Anctil, JC
Clark, BG
Arsenault, CJ
机构
[1] Dr Leon Richard Oncol Ctr, Moncton, NB E1C 8X3, Canada
[2] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
关键词
brachytherapy; Ir-192; anisotropy; thermoluminescent dosimetry;
D O I
10.1118/1.598457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Experimental data related to the dosimetric characteristics of Ir-192 brachytherapy sources are Limited. The aim of this work was to obtain the dosimetry functions required by the American Association of Physicists in Medicine Task Group 43 for both a low and a high dose-rate iridium-192 brachytherapy source through dose measurements in a water-equivalent phantom. Dose measurements have been performed using lithium fluoride thermoluminescent detectors positioned in a polystyrene phantom at distances from the source that vary from 1 to 10 cm, with 1 cm intervals, and at angles that vary from 0 degrees to 170 degrees with 10 degrees intervals. The anisotropy functions, radial dose functions, and dose rate constants were determined for both brachytherapy sources. The precision of results obtained on those relatively fine intervals of angles and distances provides clinics with the possibility to use and interpolate the complete data sets for treatment planning. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)02312-8].
引用
收藏
页码:2279 / 2287
页数:9
相关论文
共 22 条
[1]
Anderson L. L., 1990, INT BRACH PHYS BIOL
[2]
BALTAS D, 1993, ACTIVITY SPECIAL REP, V3, P2
[3]
EZZELL G, 1989, BRACHYTHERAPY, V2, P61
[4]
EZZELL GA, 1993, ENDOCUR HYPERTHERM O, V9, P233
[5]
Fox R. A., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P57
[6]
International Commission on Radiation Units and Measurements - ICRU, 1976, 24 ICRU
[7]
TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) :2015-2036
[8]
THERMOLUMINESCENCE DOSIMETRY OF THERAPEUTIC X-RAYS WITH LIF RIBBONS AND RODS [J].
KRON, T ;
METCALFE, P ;
WONG, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :833-845
[9]
INSTRUMENTATION AND DOSIMETER-SIZE ARTIFACTS IN QUANTITATIVE THERMOLUMINESCENCE DOSIMETRY OF LOW-DOSE FIELDS [J].
MEIGOONI, AS ;
MISHRA, V ;
PANTH, H ;
WILLIAMSON, J .
MEDICAL PHYSICS, 1995, 22 (05) :555-561
[10]
INFLUENCE OF THE VARIATION OF ENERGY-SPECTRA WITH DEPTH IN THE DOSIMETRY OF IR-192 USING LIF TLD [J].
MEIGOONI, AS ;
MELI, JA ;
NATH, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10) :1159-1170