A study of an electronic nose for detection of lung cancer based on a virtual SAW gas sensors array and imaging recognition method

被引:113
作者
Chen, X
Cao, MF
Li, Y
Hu, WJ
Wang, P
Ying, KJ
Pan, HM
机构
[1] Zhejiang Univ, Dept Biomed Engn, Biomed Engn Key Lab Educ Minist, Biosensor Natl Special Lab, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Zhejiang Run Run Shaw Hosp, Hangzhou 310027, Peoples R China
关键词
electronic nose; breath detection; lung cancer; virtual sensors array; non-invasive detection;
D O I
10.1088/0957-0233/16/8/001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we propose an electronic nose for non-invasive detection and diagnosis of lung cancer based on a kind of virtual array of surface acoustic wave (SAW) gas sensors and an imaging recognition method. It includes a gas path constructed from a two-bag system, solid phase micro extraction (SPME) and a capillary column to pre-concentrate and separate volatile organic compounds (VOCs) in patients' exhaled air. A pair of SAW sensors, one coated with a thin polyisobutylene (PIB) film, is used to detect chemical compounds. Eleven VOCs that are validated as the markers of lung cancer according to a pathology study can be detected qualitatively and quantitatively by this electronic nose. Then, an improved artificial neural network (ANN) algorithm combined with an imaging method is proposed for the recognition of patients. In addition, the concept of a virtual sensors array based on SAW sensors using a capillary column separation technique and imaging is also proposed to simulate a large scale of sensor array response. Finally this e-nose is calibrated by these 11 VOCs separated in three concentrations and is used to diagnose lung cancer patients in Run Run Shaw hospital. The experimental results show that this kind of electronic nose is effective in the recognition of lung cancer patients.
引用
收藏
页码:1535 / 1546
页数:12
相关论文
共 17 条
[11]   BREATH TESTS IN MEDICINE [J].
PHILLIPS, M .
SCIENTIFIC AMERICAN, 1992, 267 (01) :74-79
[12]   A novel method for diabetes diagnosis based on electronic nose [J].
Ping, W ;
Yi, T ;
Xie, HB ;
Shen, FR .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) :1031-1036
[13]   Improved probabilistic neural network algorithm for chemical sensor array pattern recognition [J].
Shaffer, RE ;
Rose-Pehrsson, SL .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4263-4271
[14]   Design of SAW delay lines for sensors [J].
Soluch, W .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 67 (1-3) :60-64
[15]  
STAPLES EJ, 2000, 2AEA4 AC SOC AM
[16]   SURFACE ACOUSTIC-WAVE PROBE FOR CHEMICAL-ANALYSIS .1. INTRODUCTION AND INSTRUMENT DESCRIPTION [J].
WOHLTJEN, H ;
DESSY, R .
ANALYTICAL CHEMISTRY, 1979, 51 (09) :1458-1464
[17]   Diagnosis of diabetes by image detection of breath using gas-sensitive laps [J].
Zhang, QT ;
Wang, P ;
Li, JP ;
Gao, XG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :249-256