Poly(styrene-block-vinylpyrrolidone) beads as a versatile material for simple fabrication of optical nanosensors

被引:78
作者
Borisov, Sergey M. [1 ]
Mayr, Torsten [1 ]
Klimant, Ingo [1 ]
机构
[1] Graz Univ Technol, Inst Analyt Chem & Radiochem, A-8010 Graz, Austria
关键词
D O I
10.1021/ac071374e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A versatile platform for designing optical nanosensors, is proposed. The "sensing chemistries" are entrapped into the poly(styrene-block-vinylpyrrolidone) nanoheads having the average size of 245 run in aqueous media. Addressable staining into the core or the shell of the beads results in nanosensors for essential analytes such as dissolved oxygen, temperature, pH, chloride, and copper ions. Two immobilization procedures are developed: staining in the polystyrene core is performed from a tetrahydrofuran/water mixture (50:50 v/v) and staining in the poly(vinylpyrrolidone) shell is achieved by using the ethanol/water mixture (70:30 v/v). The oxygen and temperature indicators should be preferably immobilized into the core, whereas nanosensors for ions are manufactured by staining into the shell. In the case of the lipophilic pH indicators both procedures result in similar pK(a) values. The unique properties of the beads make them promising for sensing and imaging even in very complex media, multianalyte sensing, and monitoring of very fast processes.
引用
收藏
页码:573 / 582
页数:10
相关论文
共 61 条
[31]   Luminescence lifetime imaging of oxygen, pH, and carbon dioxide distribution using optical sensors [J].
Liebsch, G ;
Klimant, I ;
Frank, B ;
Holst, G ;
Wolfbeis, OS .
APPLIED SPECTROSCOPY, 2000, 54 (04) :548-559
[32]   Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing [J].
Liebsch, G ;
Klimant, I ;
Krause, C ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4354-4363
[33]  
Liebsch G, 1999, ADV MATER, V11, P1296, DOI 10.1002/(SICI)1521-4095(199910)11:15<1296::AID-ADMA1296>3.0.CO
[34]  
2-B
[35]   Multi-ion imaging using fluorescent sensors in a microtiterplate array format [J].
Mayr, T ;
Liebsch, G ;
Klimant, I ;
Wolfbeis, OS .
ANALYST, 2002, 127 (02) :201-203
[36]   Fluorimetric determination of copper(II) in aqueous solution using lucifer yellow CH as selective metal reagent [J].
Mayr, T ;
Wencel, D ;
Werner, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (01) :44-48
[37]   Dye-encapsulating liposomes as fluorescence-based oxygen nanosensors [J].
McNamara, KP ;
Rosenzweig, Z .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4853-4859
[38]   Fluorescence-based thin plastic film ion-pair sensors for oxygen [J].
Mills, A ;
Thomas, M .
ANALYST, 1997, 122 (01) :63-68
[39]  
Mohr G J, 1995, J Fluoresc, V5, P135, DOI 10.1007/BF00727530
[40]   UNUSUAL SELECTIVITY IN SOLUBILIZATION BY BLOCK COPOLYMER MICELLES [J].
NAGARAJAN, R ;
BARRY, M ;
RUCKENSTEIN, E .
LANGMUIR, 1986, 2 (02) :210-215