Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution

被引:64
作者
Kuettner, A
Beck, T
Drosch, T
Kettering, K
Heuschmid, M
Burgstahler, C
Claussen, CD
Kopp, AF
Schroeder, S
机构
[1] Univ Tubingen, Dept Radiol, Div Diagnost Radiol, Tubingen, Germany
[2] Univ Tubingen, Dept Internal Med, Div Cardiol, Tubingen, Germany
关键词
D O I
10.1136/hrt.2004.044735
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate image quality and clinical accuracy in detecting coronary artery lesions with a new multidetector spiral computed tomography (MDCT) generation with 16 detector slices and a temporal resolution of 188 ms. Methods: 124 consecutive patients scheduled for invasive coronary angiography (ICA) were additionally studied by MDCT ( Sensation 16 Speed 4D). MDCTs were analysed with regard to image quality and presence of coronary artery lesions. The results were compared with ICA. Results: 120 of 124 scans were successful. The image quality of all remaining 120 scans was sufficient ( mean (SD) heart rate 64.2 (9.8) beats/min, range 43 - 95). The mean calcium mass was 167 ( 223) mg ( range 0 - 1038). Thirteen coronary segments were evaluated for each patient ( 1560 segments in total). Image quality was graded as follows: excellent, 422 (27.1%) segments; good, 540 (34.6%) segments; moderate, 277 (17.7%) segments; heavily calcified, 215 (13.8%) segments; and blurred, 106 (6.8%) segments. ICA detected 359 lesions with a diameter stenosis. 50% and MDCT detected 304 of 359 (85%). Sensitivity, specificity, and positive and negative predictive values were 85%, 98%, 91%, and 96%, respectively. The correct clinical diagnosis ( presence or absence of at least one stenosis. 50%) was obtained for 110 of 120 (92%) patients. Conclusions: MDCT image quality can be further improved with 16 slices and faster gantry rotation time. These results in an unselected population underline the potential of MDCT to become a non-invasive diagnostic alternative, especially for the exclusion of coronary artery disease, in the near future.
引用
收藏
页码:938 / 941
页数:4
相关论文
共 10 条
[1]   Editorial comment - Detection of coronary stenoses by multidetector computed tomography: It's all about resolution [J].
Achenbach, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :840-841
[2]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[3]   Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography [J].
Budoff, MJ ;
Achenbach, S ;
Duerinckx, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1867-1878
[4]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[5]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[6]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247
[7]   Accuracy of thin-slice computed tomography in the detection of coronary stenoses [J].
Martuscelli, E ;
Romagnoli, A ;
D'Eliseo, A ;
Razzini, C ;
Tomassini, M ;
Sperandio, M ;
Simonetti, G ;
Romeo, F .
EUROPEAN HEART JOURNAL, 2004, 25 (12) :1043-1048
[8]   Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris [J].
Mollet, NR ;
Cademartiri, F ;
Nieman, K ;
Saia, F ;
Lemos, PA ;
McFadden, EP ;
Pattynama, PMT ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) :2265-2270
[9]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054
[10]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666