Pulsed amperometric detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate with microfabricated disposable silver working electrodes in ion chromatography

被引:42
作者
Cheng, J [1 ]
Jandik, P [1 ]
Avdalovic, N [1 ]
机构
[1] Dionex Chem Corp, Sunnyvale, CA 94088 USA
关键词
disposable electrodes; thin film electrodes; silver electrodes; ion chromatography; pulsed amperometric detection; sulfide; cyanide; bromide; thiosulfate; iodide; thiocyanate;
D O I
10.1016/j.aca.2004.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors introduce a new type of silver electrodes. The new electrodes are designed to be disposable and as such they are used only for a limited period of time, usually 5-7 days, and then discarded. Manual polishing, which is required with non-disposable electrodes, is not necessary with disposable electrodes. This manuscript describes the development of pulsed amperometric detection waveforms that make it possible to utilize disposable silver electrodes in the chromatographic detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate. Also discussed is an evaluation of analytical performance of the electrodes with the newly developed waveforms. The detection limits were found to be 1 ppb (S2-), 2 ppb (CN-), 5 ppb (Br-, S2O32- and I-) and 10 ppb (SCN-) for a 10 mu l injection volume. Calibration plots for S2-, CN-, Br- and S2O32- are linear from their respective detection limits up to 50-100 ppm. The linear calibration for I- and SCN- can be obtained from the detection limits up to 10 ppm. Reproducible long-term performance was confirmed in a 2-week experiment with 10 mu l injections of 1 ppm CN-. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 18 条
[1]   Determination of cyanide by cathodic stripping voltammetry at a rotating silver disk electrode [J].
Anh, NBH ;
Sharp, M .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :145-152
[2]  
BARD AJ, 1980, ELECTROCHEMICAL METH, P58
[3]   SIMULTANEOUS DETERMINATION OF FREE SULFIDE AND CYANIDE BY ION CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOND, AM ;
HERITAGE, ID ;
WALLACE, GG ;
MCCORMICK, MJ .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :582-585
[4]   SIMULTANEOUS DETERMINATION OF CYANIDE AND SULFIDE WITH RAPID DIRECT-CURRENT POLAROGRAPHY [J].
CANTERFORD, DR .
ANALYTICAL CHEMISTRY, 1975, 47 (01) :88-92
[5]   Development and characterization of microfabricated disposable gold working electrodes for high-performance ion chromatography and integrated pulsed amperometric detection [J].
Cheng, J ;
Jandik, P ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :572-579
[6]   Ion chromatographic determination of sulfide and cyanide in real matrices by using pulsed amperometric detection on a silver electrode [J].
Giuriati, C ;
Cavalli, S ;
Gorni, A ;
Badocco, D ;
Pastore, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :105-112
[7]   AMPEROMETRIC DETECTION OF SIMPLE ALCOHOLS IN AQUEOUS-SOLUTIONS BY APPLICATION OF A TRIPLE-PULSE POTENTIAL WAVEFORM AT PLATINUM-ELECTRODES [J].
HUGHES, S ;
MESCHI, PL ;
JOHNSON, DC .
ANALYTICA CHIMICA ACTA, 1981, 132 (DEC) :1-10
[8]   Differential pulse voltammetric determination of trace Te(IV) at a poly (3,3′-diaminobenzidine) film modified gold electrode in flow systems [J].
Khoo, SB ;
Ye, RD .
ANALYTICA CHIMICA ACTA, 2002, 453 (02) :209-220
[9]  
LAI X, 1991, HDB CHEM ANAL, P590
[10]   DETERMINATION OF IODIDE AND THIOSULFATE BY PAIRED-ION, REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET ABSORBENCY, ELECTROCHEMICAL, AND CONDUCTIMETRIC DETECTION [J].
LOOKABAUGH, M ;
KRULL, IS ;
LACOURSE, WR .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :301-312