Development and characterization of microfabricated disposable gold working electrodes for high-performance ion chromatography and integrated pulsed amperometric detection

被引:32
作者
Cheng, J [1 ]
Jandik, P [1 ]
Avdalovic, N [1 ]
机构
[1] Dionex Chem Corp, Sunnyvale, CA 94088 USA
关键词
D O I
10.1021/ac0204754
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a new type of microfabricated thin-film electrode on polymeric substrates. The microfabrication process allows for inexpensive and reproducible mass production of disposable working electrodes for high-performance ion chromatography and integrated pulsed amperometric detection (IPAD). These microfabricated electrodes are disposable and have been optimized for use in flow-through low-dead-volume electrochemical cells. The analytical performance of microfabricated gold electrodes was characterized with the help of the IPAD method for amino acid detection under alkaline conditions required for anion-exchange separations. When used with a new optimized six-potential IPAD waveform, the electrodes functioned properly for weeks. Compared to nondisposable working electrodes, the disposable working electrodes generated equal or better results in the limit of detection, linearity of calibration, and reproducibility. Disposable electrodes make it possible to avoid polishing and reconditioning, which are required with nondisposable electrodes.
引用
收藏
页码:572 / 579
页数:8
相关论文
共 26 条
[1]   SELF-ASSEMBLED MONOLAYERS CONTAINING POLYDIACETYLENES [J].
BATCHELDER, DN ;
EVANS, SD ;
FREEMAN, TL ;
HAUSSLING, L ;
RINGSDORF, H ;
WOLF, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (03) :1050-1053
[2]   Modulation of electronic coupling through self-assembled monolayers via internal chemical modification [J].
Cheng, J ;
SaghiSzabo, G ;
Tossell, JA ;
Miller, CJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (03) :680-684
[3]   STM STUDY OF THE SURFACE-MORPHOLOGY OF GOLD ON MICA [J].
CHIDSEY, CED ;
LOIACONO, DN ;
SLEATOR, T ;
NAKAHARA, S .
SURFACE SCIENCE, 1988, 200 (01) :45-66
[4]   An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography [J].
Clarke, AP ;
Jandik, P ;
Rocklin, RD ;
Liu, Y ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2774-2781
[5]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[6]   THEORETICAL AND PRACTICAL LIMITATIONS ON THE OPTIMIZATION OF AMPEROMETRIC DETECTORS [J].
ELBICKI, JM ;
MORGAN, DM ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :978-985
[7]   Self-assembly and bonding of alkanephosphonic acids on the native oxide surface of titanium [J].
Gawalt, ES ;
Avaltroni, MJ ;
Koch, N ;
Schwartz, J .
LANGMUIR, 2001, 17 (19) :5736-5738
[8]   THEORETICAL COMPARISON OF THE PERFORMANCE OF ELECTROCHEMICAL FLOW-THROUGH DETECTORS [J].
HANEKAMP, HB ;
DEJONG, HG .
ANALYTICA CHIMICA ACTA, 1982, 135 (02) :351-354
[9]   Microfabricated recessed microdisk electrodes: Characterization in static and convective solutions [J].
Henry, CS ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :550-556
[10]   Selective electrochemical detection using a split disk array electrode in a thin-layer radial flow system [J].
Iwasaki, Y ;
Niwa, O ;
Morita, M ;
Tabei, H ;
Kissinger, PT .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3797-3800