Diffusion coefficient measurement in a microfluidic analyzer using dual-beam microscale-refractive index gradient detection - Application to on-chip molecular size determination

被引:26
作者
Costin, CD [1 ]
Olund, RK [1 ]
Staggemeier, BA [1 ]
Torgerson, AK [1 ]
Synovec, RE [1 ]
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
关键词
diffusion coefficients; microfluidics; chip technology; refractive index gradient detection; detection; LC; poly(ethylene glycol);
D O I
10.1016/S0021-9673(03)01101-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a microchip-based detection scheme to determine the diffusion coefficient and molecular mass (to the extent correlated to molecular size) of analytes of interest. The device works by simultaneously measuring the refractive index gradient (RIG) between adjacent laminar flows at two different positions along a microchannel. The device, referred to as a microscale molecular mass sensor (mu-MMS), takes advantage of laminar flow conditions where the mixing of two streams occurs essentially by diffusion across the boundary between the two streams. Two flows merge on the microchip, one containing solvent only, referred to as the mobile phase stream and one which contains the analyte(s) of interest in the solvent, i.e. the sample stream. As these two streams merge and flow parallel to each other down the microchannel a RIG is created by the concentration gradient. The RIG is further influenced by analyte diffusion from the sample stream into the mobile phase stream. Measuring the RIG at a position close to the merging point (upstream signal) and simultaneously a selected distance further down the microchannel (downstream signal) provides real-time data related to the extent a given analyte has diffused, which can be readily correlated to analyte molecular mass by taking the ratio of the downstream-to-upstream signals. For the dual-beam RIG measurements, a diode laser output is coupled to a single mode fiber optic splitter with two output fibers. Light from each fiber passes through a graded refractive index (GRIN) lens forming a collimated beam that then passes through the microchannel and then on to a position sensitive detector (PSD). The RIG at both detection positions deflects the two collimated probe beams. The deflection angle of each beam is then measured on two separate PSDs. The mu-MMS was evaluated using polyethylene glycols (PEGs), sugars, and as a detector for size-exclusion chromatography (SEC). Peak purity can be readily identified using the mu-MMS with SEC. The limit of detection was 0.9 ppm (PEG at 11 840 g/mol) at the upstream detection position corresponding to a RI limit of detection (LOD) (3sigma) of 7(.)10(-8) RI. The pathlength for the RIG measurement was 200 pm and the angular LOD was 0.23 murad with a detection volume of 8 nI at both positions. The average molecular mass resolution was 9% (relative standard deviation) for a series of PEGs ranging in molecular mass from 106 to 22 800 g/mol. With this excellent mass resolution, small molecules such as monosaccharides, disaccharides, and so on, are readily distinguished. The sensor is demonstrated to readily determine unknown diffusion coefficients. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 91
页数:15
相关论文
共 34 条
[21]   MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS - A NOVEL CONCEPT FOR CHEMICAL SENSING [J].
MANZ, A ;
GRABER, N ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :244-248
[22]   Breaking the 10-7 barrier for RI measurements in nanoliter volumes [J].
Markov, D ;
Begari, D ;
Bornhop, DJ .
ANALYTICAL CHEMISTRY, 2002, 74 (20) :5438-5441
[23]   RADIAL MEASUREMENT OF HYDRODYNAMICALLY GENERATED CONCENTRATION PROFILES FOR MOLECULAR-WEIGHT DETERMINATION [J].
MURUGAIAH, V ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2130-2137
[24]   MOLECULAR-WEIGHT SENSING OF POLYETHYLENE GLYCOLS BY FLOW-INJECTION ANALYSIS AND REFRACTIVE-INDEX GRADIENT DETECTION [J].
MURUGAIAH, V ;
SYNOVEC, RE .
ANALYTICA CHIMICA ACTA, 1991, 246 (01) :241-249
[25]   NANOLITER VOLUME SEQUENTIAL DIFFERENTIAL CONCENTRATION GRADIENT DETECTOR [J].
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2796-2801
[26]   OBSERVATION OF CONCENTRATION GRADIENTS BY THE LASER-BEAM DEFLECTION SENSOR [J].
PAWLISZYN, J ;
WEBER, MF ;
DIGNAM, MJ ;
MANDELIS, A ;
VENTER, RD ;
PARK, SM .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :236-239
[28]   REFRACTIVE-INDEX GRADIENT DETECTION OF BIOPOLYMERS SEPARATED BY HIGH-TEMPERATURE LIQUID-CHROMATOGRAPHY [J].
RENN, CN ;
SYNOVEC, RE .
JOURNAL OF CHROMATOGRAPHY, 1991, 536 (1-2) :289-301
[29]   Chip-scale universal detection based on backscatter interferometry [J].
Swinney, K ;
Markov, D ;
Bornhop, DJ .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2690-2695