Wide-field lensless fluorescent microscopy using a tapered fiber-optic faceplate on a chip

被引:58
作者
Coskun, Ahmet F. [1 ]
Sencan, Ikbal [1 ]
Su, Ting-Wei [1 ]
Ozcan, Aydogan [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Calif NanoSyst Inst CNSI, Los Angeles, CA 90095 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
CIRCULATING TUMOR-CELLS;
D O I
10.1039/c0an00926a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate lensless fluorescent microscopy over a large field-of-view of similar to 60 mm(2) with a spatial resolution of < 4 mu m. In this on-chip fluorescent imaging modality, the samples are placed on a fiber-optic faceplate that is tapered such that the density of the fiber-optic waveguides on the top facet is > 5 fold larger than the bottom one. Placed on this tapered faceplate, the fluorescent samples are pumped from the side through a glass hemisphere interface. After excitation of the samples, the pump light is rejected through total internal reflection that occurs at the bottom facet of the sample substrate. The fluorescent emission from the sample is then collected by the smaller end of the tapered faceplate and is delivered to an opto-electronic sensor-array to be digitally sampled. Using a compressive sampling algorithm, we decode these raw lensfree images to validate the resolution (< 4 mu m) of this on-chip fluorescent imaging platform using microparticles as well as labeled Giardia muris cysts. This wide-field lensfree fluorescent microscopy platform, being compact and high-throughput, might provide a valuable tool especially for cytometry, rare cell analysis (involving large area microfluidic systems) as well as for microarray imaging applications.
引用
收藏
页码:3512 / 3518
页数:7
相关论文
共 17 条
[1]   Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution [J].
Bishara, Waheb ;
Su, Ting-Wei ;
Coskun, Ahmet F. ;
Ozcan, Aydogan .
OPTICS EXPRESS, 2010, 18 (11) :11181-11191
[2]   Near-optimal signal recovery from random projections: Universal encoding strategies? [J].
Candes, Emmanuel J. ;
Tao, Terence .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (12) :5406-5425
[3]   Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects [J].
Coskun, Ahmet F. ;
Sencan, Ikbal ;
Su, Ting-Wei ;
Ozcan, Aydogan .
OPTICS EXPRESS, 2010, 18 (10) :10510-10523
[4]   Wide field-of-view lens-free fluorescent imaging on a chip [J].
Coskun, Ahmet F. ;
Su, Ting-Wei ;
Ozcan, Aydogan .
LAB ON A CHIP, 2010, 10 (07) :824-827
[5]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[6]   FOURIER-TRANSFORM HOLOGRAPHIC MICROSCOPE [J].
HADDAD, WS ;
CULLEN, D ;
SOLEM, JC ;
LONGWORTH, JW ;
MCPHERSON, A ;
BOYER, K ;
RHODES, CK .
APPLIED OPTICS, 1992, 31 (24) :4973-4978
[7]   Optofluidic microscopy - a method for implementing a high resolution optical microscope on a chip [J].
Heng, Xin ;
Erickson, David ;
Baugh, L. Ryan ;
Yaqoob, Zahid ;
Sternberg, Paul W. ;
Psaltis, Demetri ;
Yang, Changhuei .
LAB ON A CHIP, 2006, 6 (10) :1274-1276
[8]   An Interior-Point Method for Large-Scale l1-Regularized Least Squares [J].
Kim, Seung-Jean ;
Koh, K. ;
Lustig, M. ;
Boyd, Stephen ;
Gorinevsky, Dimitry .
IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2007, 1 (04) :606-617
[9]   Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications [J].
Mudanyali, Onur ;
Tseng, Derek ;
Oh, Chulwoo ;
Isikman, Serhan O. ;
Sencan, Ikbal ;
Bishara, Waheb ;
Oztoprak, Cetin ;
Seo, Sungkyu ;
Khademhosseini, Bahar ;
Ozcan, Aydogan .
LAB ON A CHIP, 2010, 10 (11) :1417-1428
[10]   Isolation of rare circulating tumour cells in cancer patients by microchip technology [J].
Nagrath, Sunitha ;
Sequist, Lecia V. ;
Maheswaran, Shyamala ;
Bell, Daphne W. ;
Irimia, Daniel ;
Ulkus, Lindsey ;
Smith, Matthew R. ;
Kwak, Eunice L. ;
Digumarthy, Subba ;
Muzikansky, Alona ;
Ryan, Paula ;
Balis, Ulysses J. ;
Tompkins, Ronald G. ;
Haber, Daniel A. ;
Toner, Mehmet .
NATURE, 2007, 450 (7173) :1235-U10