Tribological study on new therapeutic bionic lubricants

被引:24
作者
Hua, Z. K. [1 ]
Su, S. H. [1 ]
Zhang, J. H. [1 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
基金
中国国家自然科学基金;
关键词
therapeutic bionic lubricants; bionic artificial joint system; membrane; boundary lubrication; biocompatibility;
D O I
10.1007/s11249-007-9247-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
New therapeutic bionic lubricants for artificial joint lubrication and the treatment of particle-induced osteolysis were developed. In this study, their tribological characteristics and mechanisms have been investigated. The tribological experimental results show that the therapeutic lubricants have the best anti-wear performance among the lubricants tested, such as hyaluronic acid (HA) and bovine serum. Some self-assembled membranes were found on the surfaces of the cups, which might contribute to the high lubrication performance of the therapeutic lubricants. The calculated film thickness of therapeutic lubricants is about 0.310 mu m, which is still in the boundary lubrication region. The preliminary biological experiments show that therapeutic lubricants have good biocompatibility. It is necessary to do more experimental work in the future to investigate the formation of the membrane and the medical performance of the therapeutic bionic lubricants for better understanding of the effects of the undesired reactions induced by the wear debris.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 38 条
  • [1] Wear of prosthetic joint materials in various lubricants
    Ahlroos, T
    Saikko, V
    [J]. WEAR, 1997, 211 (01) : 113 - 119
  • [2] AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, V276, P6
  • [3] Synovial fluid analysis
    Brannan, SR
    Jerrard, DA
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2006, 30 (03) : 331 - 339
  • [4] A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty
    Cawley, J
    Metcalf, JEP
    Jones, AH
    Band, TJ
    Skupien, DS
    [J]. WEAR, 2003, 255 : 999 - 1006
  • [5] Knee and hip kinetics during normal stair climbing
    Costigan, PA
    Deluzio, KJ
    Wyss, UP
    [J]. GAIT & POSTURE, 2002, 16 (01) : 31 - 37
  • [6] HARRIS WH, 1995, CLIN ORTHOP RELAT R, P46
  • [7] THERMODYNAMIC PROPERTIES OF AQUEOUS ALPHA-CHYMOTRYPSIN SOLUTIONS FROM MEMBRANE OSMOMETRY MEASUREMENTS
    HAYNES, CA
    TAMURA, K
    KORFER, HR
    BLANCH, HW
    PRAUSNITZ, JM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (02) : 905 - 912
  • [8] Osteoblast proliferation and maturation by bisphosphonates
    Im, GI
    Qureshi, SA
    Kenney, J
    Rubash, HE
    Shanbhag, AS
    [J]. BIOMATERIALS, 2004, 25 (18) : 4105 - 4115
  • [9] Wear and bending strain characteristics of artificial hip joint with non-glued stem and UHMWPE femur
    Ishida, K
    Okada, K
    Hamada, Y
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2005, 29 (04): : 396 - 403
  • [10] Prediction of lubricating film thickness in UHMWPE hip joint replacements
    Jalali-Vahid, D
    Jagatia, M
    Jin, ZM
    Dowson, D
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (02) : 261 - 266