Comparison of cone beam computed tomography imaging with physical measures

被引:172
作者
Stratemann, S. A. [1 ]
Huang, J. C. [1 ]
Maki, K. [2 ]
Miller, A. J. [1 ]
Hatcher, D. C. [1 ]
机构
[1] Univ Calif San Francisco, Sch Dent, Dept Orofacial Sci, Div Orthodont, San Francisco, CA 94143 USA
[2] Showa Univ, Dept Orthodont, Tokyo, Japan
关键词
cone beam computed tomography; mandible; craniofacial;
D O I
10.1259/dmfr/31349994
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The goal of this study was to determine the accuracy of measuring linear distances between landmarks commonly used in orthodontic analysis on a human skull using two cone beam CT (CBCT) systems. Methods: Measurements of length were taken using volumetric data from two CBCT systems and were compared with physical measures using a calliper applied to one human adult skull. Landmarks were identified with chromium steel balls embedded at 32 cranial and 33 mandibular landmarks and the linear measures were taken with a digital calliper. The skull was then scanned with two different CBCT systems: the NewTon-(R) QR DVT 9000 (Aperio Inc, Sarasota, FL) and the Hitachi MercuRay (Hitachi Medico Technology, Tokyo, Japan). CT data including the landmark point data were threshold segmented using CyberMed's CB Works software (CB Works 1.0, CyberMed Inc., Seoul, Korea). The resulting segmentations were exported from CB Works as VRML (WRL) files to Amira software (Amira 3.1, Mercury Computer Systems GmbH, Berlin, Germany). Results: The error was small compared with the gold standard of the physical calliper measures for both the NewTom (0.07 +/- 0.41 mm) and CB MercuRay (0.00 +/- 0.22 mm) generated data. Absolute error to the gold standard was slightly positive, indicating minor compression relative to the calliper measurement. The error was slightly smaller in the CB MercuRay than in the NewTom, probably related to a broader greyscale range for describing beam attenuation in 12-bit vs 8-bit data. Conclusions: The volumetric data rendered with both CBCT systems provided highly accurate data compared with the gold standard of physical measures directly from the skulls, with less than 1% relative error.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 47 条
[1]  
ABOUDARA CL, 2003, GROWTH DEV, P60
[2]   Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties [J].
Araki, K ;
Maki, K ;
Seki, K ;
Sakamaki, K ;
Harata, Y ;
Sakaino, R ;
Okano, T ;
Seo, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) :51-59
[3]  
Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
[4]   RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[5]   Imaging modalities in x-ray computerized tomography and in selected volume tomography [J].
Carlsson, CA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :R23-R56
[6]   Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications [J].
Cavalcanti, MGP ;
Rocha, SS ;
Vannier, MW .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) :170-176
[7]   Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro [J].
Cavalcanti, MGP ;
Haller, JW ;
Vannier, MW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) :690-694
[8]   Superimposition of 3D cone-beam CT models of orthognathic surgery patients [J].
Cevidanes, LHS ;
Bailey, LJ ;
Tucker, GR ;
Styner, MA ;
Mol, A ;
Phillips, CL ;
Proffit, WR ;
Turvey, T .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (06) :369-375
[9]   Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery [J].
Cevidanes, Lucia H. S. ;
Bailey, L'Tanya J. ;
Tucker, Scott F. ;
Styner, Martin A. ;
Mol, Andre ;
Phillips, Ceib L. ;
Proffit, William R. ;
Turvey, Timothy .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (01) :44-50
[10]   Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography [J].
Farman, Allan G. ;
Scarfe, William C. .