Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties

被引:124
作者
Araki, K
Maki, K
Seki, K
Sakamaki, K
Harata, Y
Sakaino, R
Okano, T
Seo, K
机构
[1] Showa Univ, Sch Dent, Dept Radiol, Ohta Ku, Tokyo 1458515, Japan
[2] Showa Univ, Sch Dent, Dept Orthodont, Ohta Ku, Tokyo 142, Japan
[3] Hitachi Medico Technol Corp, Design Dept, Chiba, Japan
关键词
tomography; X-ray computed; radiography; dental; tomography scanners;
D O I
10.1259/dmfr/54013049
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this paper is to present the system configuration and physical properties of a new dentomaxillofacial X-ray cone beam CT system (CB MercuRay(TM)) being developed. Methods: The system consists of an image intensifier and a cone beam X-ray source. There are two different models of this system, each with a different size image intensifier, 9" or 12". Each system has three field of view (FOV) modes. The 12" system has facial (F), panoramic (P) and implant (1) FOV modes. The 9" system has P, I and dental (D) modes. Images produced by these systems consist of 5 12 X 512 X 512 isotropic voxels. Physical properties such as resolution, noise and distortion of the images were evaluated in this study. Modulation transfer function (MTF) was measured using Boone's method. Image noise was measured as the standard deviation of the CT value in water. Circularity of the axial images yielded by the two models was measured using an 8 mm diameter acrylic pipe phantom. Results: The resolving power at a MTF of 0.1 in the D mode was over 2.01p mm(-1), suggesting that this system yields images of high resolution. The standard deviation of the CT value in water was approximately 80, which is thought to be greater than that of conventional CT. The circularity of images of the pipe phantom was 99% of the ideal value. Conclusion: This study shows that our newly developed cone beam CT system produces high resolution three-dimensional volumetric images that will be useful for the examination of dentomaxillofacial disorders.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 17 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]  
Baba Rika, 2001, Frontiers of Medical and Biological Engineering, V11, P177, DOI 10.1163/15685570152772450
[3]   Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[4]   Cone-beam volume CT breast imaging: Feasibility study [J].
Chen, B ;
Ning, R .
MEDICAL PHYSICS, 2002, 29 (05) :755-770
[5]   Image characteristics and effective dose estimation of a cone beam CT using a video-fluoroscopic system [J].
Endo, M ;
Nishizawa, K ;
Iwai, K ;
Matsumoto, M ;
Yoshida, K ;
Satoh, K ;
Matsusita, M ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :686-690
[6]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[7]  
Endo M, 1998, Radiat Med, V16, P7
[8]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[9]   Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data [J].
Grass, M ;
Koppe, R ;
Klotz, E ;
Proksa, R ;
Kuhn, MH ;
Aerts, H ;
Op de Beek, J ;
Kemkers, R .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (06) :311-321
[10]   A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine [J].
Hashimoto, K ;
Arai, Y ;
Iwai, K ;
Araki, M ;
Kawashima, S ;
Terakado, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03) :371-377