Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques

被引:31
作者
Hiratsuka, A
Kojima, K
Suzuki, H
Muguruma, H
Ikebukuro, K
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Univ Tsukuba, Inst Mat Sci, Tsukuba Sci City 3058573, Japan
[3] Shibaura Inst Technol, Dept Elect Engn, Minato Ku, Tokyo 1088548, Japan
关键词
D O I
10.1039/b008036p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed an integrated array of needle-type biosensors employing a novel process of fabrication, comprising conventional semiconductor fabrication and micromachining technology. Amperometric sensing electrodes with plasma-polymerized films and a thin-film Ag/AgCl reference electrode were directly integrated on a glass substrate with thin-film process, e.g., sputtering. An enzyme was immobilized on the electrode via the plasma-polymerized film, which was deposited directly on the substrate using a dry process. The novel thin-film Ag/AgCl reference electrode showed stable potentials in concentrated chloride solutions for a long period. The plasma-polymerized film is considered to play an important role as an interfacial design between the sensing electrode and the immobilized enzyme considering that the film is extremely thin, adheres well to the substrate (electrode) and has a highly cross-linked network structure and functional groups, such as amino groups. The results showed increments of the sensor signal, probably because the plasma-polymerized film allowed a large amount of enzyme to be immobilized. The greatest advantage is that the process can permit the mass production of high-quality biosensors at a low cost.
引用
收藏
页码:658 / 663
页数:6
相关论文
共 40 条
[1]   DEVELOPMENT OF A NEEDLE-TYPE BIOSENSOR FOR INTRAVASCULAR GLUCOSE MONITORING [J].
ABDELHAMID, I ;
ATANASOV, P ;
WILKINS, E .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :45-54
[2]  
Anderson JL, 1998, ANAL CHEM, V70, p519R
[3]  
[Anonymous], ANAL CHEM
[4]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[5]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[6]   Platinum-catalyzed enzyme electrodes immobilized on gold using self-assembled layers [J].
Gooding, JJ ;
Praig, VG ;
Hall, EAH .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2396-2402
[7]   Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorption-controlled mechanism [J].
Hall, SB ;
Khudaish, EA ;
Hart, AL .
ELECTROCHIMICA ACTA, 1998, 43 (5-6) :579-588
[8]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[9]   Mass transport behavior of electrochemical species through plasma-polymerized thin film on platinum electrode [J].
Hiratsuka, A ;
Muguruma, H ;
Nagata, R ;
Nakamura, R ;
Sato, K ;
Uchiyama, S ;
Karube, I .
JOURNAL OF MEMBRANE SCIENCE, 2000, 175 (01) :25-34
[10]  
Hiratsuka A, 1998, ELECTROANAL, V10, P231, DOI 10.1002/(SICI)1521-4109(199804)10:4<231::AID-ELAN231>3.0.CO