Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques

被引:31
作者
Hiratsuka, A
Kojima, K
Suzuki, H
Muguruma, H
Ikebukuro, K
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Univ Tsukuba, Inst Mat Sci, Tsukuba Sci City 3058573, Japan
[3] Shibaura Inst Technol, Dept Elect Engn, Minato Ku, Tokyo 1088548, Japan
关键词
D O I
10.1039/b008036p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed an integrated array of needle-type biosensors employing a novel process of fabrication, comprising conventional semiconductor fabrication and micromachining technology. Amperometric sensing electrodes with plasma-polymerized films and a thin-film Ag/AgCl reference electrode were directly integrated on a glass substrate with thin-film process, e.g., sputtering. An enzyme was immobilized on the electrode via the plasma-polymerized film, which was deposited directly on the substrate using a dry process. The novel thin-film Ag/AgCl reference electrode showed stable potentials in concentrated chloride solutions for a long period. The plasma-polymerized film is considered to play an important role as an interfacial design between the sensing electrode and the immobilized enzyme considering that the film is extremely thin, adheres well to the substrate (electrode) and has a highly cross-linked network structure and functional groups, such as amino groups. The results showed increments of the sensor signal, probably because the plasma-polymerized film allowed a large amount of enzyme to be immobilized. The greatest advantage is that the process can permit the mass production of high-quality biosensors at a low cost.
引用
收藏
页码:658 / 663
页数:6
相关论文
共 40 条
[11]  
2-B
[12]  
Hiratsuka A, 1999, ELECTROANAL, V11, P1098, DOI 10.1002/(SICI)1521-4109(199911)11:15<1098::AID-ELAN1098>3.3.CO
[13]  
2-E
[14]  
Hu YB, 1997, J NEUROCHEM, V68, P1745
[15]   Initial evaluation of a 290-μm diameter subcutaneous glucose sensor:: Glucose monitoring with a biocompatible, flexible-wire, enzyme-based amperometric microsensor in diabetic and nondiabetic humans [J].
Ishikawa, M ;
Schmidtke, DW ;
Raskin, P ;
Quinn, CAP .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 1998, 12 (06) :295-301
[16]   Improvement of the silver/silver chloride reference electrode and its application to pH measurement [J].
Ito, S ;
Hachiya, H ;
Baba, K ;
Asano, Y ;
Wada, H .
TALANTA, 1995, 42 (11) :1685-1690
[17]  
IVES DJG, 1961, REFERENCE ELECT
[18]  
IWUHA E, 1997, BIOSENS BIOELECTRON, V12, P749
[19]   Mass producible miniaturized flow through a device with a biosensor array [J].
Jobst, G ;
Moser, I ;
Svasek, P ;
Varahram, M ;
Trajanoski, Z ;
Wach, P ;
Kotanko, P ;
Skrabal, F ;
Urban, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) :121-125
[20]   Thin-film microbiosensors for glucose-lactate monitoring [J].
Jobst, G ;
Moser, I ;
Varahram, M ;
Svasek, P ;
Aschauer, E ;
Trajanoski, Z ;
Wach, P ;
Kotanko, P ;
Skrabal, F ;
Urban, G .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3173-3179