Determination of tertiary amines based on pH junctions and field amplification in capillary electrophoresis with electrochemiluminescence detection

被引:32
作者
Sreedhar, M [1 ]
Lin, YW [1 ]
Tseng, WL [1 ]
Chang, HT [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 106, Taiwan
关键词
capillary electrophoresis; indium tin oxide electrode; poly(dimethylsiloxane)-Al2O3 electrochemiluminescence cell; stacking; trialkylamines; tris(2,2 '-bipyridyl) ruthenium(II);
D O I
10.1002/elps.200500009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A stacking approach based on pH junction and field amplification has been developed for determining amines by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. A two-electrode configuration was employed with an indium/tin oxide-coated glass as a working electrode and a platinum wire as a pseudoreference electrode. The ECL system also contains a flow cell (poly(dimethylsiloxane)-aluminum oxide) that was made from a mixture of Sylgard 184 silicone elastomer, a curing agent, and aluminum oxide. In order to improve the sensitivity of the present CE-ECL system using tris(2,2'-bipyridyl) ruthenium(II) (Ru(bPY)(3)(2+)), a stacking approach based on pH junctions and field amplification has been tested for the analysis of triethylamine (TEA), tripropylamine (TPA), and tributylamine (TBA). Once amines (cations) prepared in citric acid solution (pH < 4.0) migrate towards the background electrolyte (15 mm sodium borate at pH 8.0), they slow down and are stacked at the boundary as a result of deprotonation and decreases in the electric field. By applying hydrodynamic injection of the sample for 60 s, this method provides the concentration limits of detection (signal-to-noise ratio = 3) of 24, 20, and 32 nm for TEA, TPA, and TBA, respectively. The results indicate that the stacking CE-ECL system is better than CE-ECL systems using a two-electrode configuration and comparable to those using a three-electrode configuration. The potential applicability of the new and low-cost CE-ECL system has been demonstrated by the determination of 1.0 mu m lidocaine, a local anesthetic drug, in urine without any tedious sample preparation.
引用
收藏
页码:2984 / 2990
页数:7
相关论文
共 44 条
[31]  
Liu JF, 2002, CLIN CHEM, V48, P1049
[32]  
Osbourn DM, 2000, ELECTROPHORESIS, V21, P2768, DOI 10.1002/1522-2683(20000801)21:14<2768::AID-ELPS2768>3.0.CO
[33]  
2-P
[34]   Experimental studies of electroosmotic flow dynamics during sample stacking for capillary electrophoresis [J].
Pittman, JL ;
Gessner, HJ ;
Frederick, KA ;
Raby, EM ;
Batts, JB ;
Gilman, SD .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3531-3538
[35]   Microchip capillary electrophoresis with an integrated indium tin oxide electrode-based electrochemiluminescence detector [J].
Qiu, HB ;
Yan, JL ;
Sun, XH ;
Liu, JF ;
Cao, WD ;
Yang, XR ;
Wang, EK .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5435-5440
[36]   Sample stacking of cationic and anionic analytes in capillary electrophoresis [J].
Quirino, JP ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :119-135
[37]   Electrochemiluminescence (ECL) [J].
Richter, MM .
CHEMICAL REVIEWS, 2004, 104 (06) :3003-3036
[38]   ELECTROGENERATED CHEMI-LUMINESCENCE .37. AQUEOUS ECL SYSTEMS BASED ON RU(2,2'-BIPYRIDINE)32+ AND OXALATE OR ORGANIC-ACIDS [J].
RUBINSTEIN, I ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1981, 103 (03) :512-516
[39]   Tris(2,2′-bipyridine)ruthenium(II) electrogenerated chemiluminescence of alkaloid type drugs with solid phase extraction sample preparation [J].
Song, QJ ;
Greenway, GM ;
McCreedy, T .
ANALYST, 2001, 126 (01) :37-40
[40]   Capillary electrophoresis with electrochemiluminescence detection of procyclidine in human urine pretreated by ion-exchange cartridge [J].
Sun, XH ;
Liu, JF ;
Cao, WD ;
Yang, XR ;
Wang, EK ;
Fung, YS .
ANALYTICA CHIMICA ACTA, 2002, 470 (02) :137-145