Combining the advantages of a multirow detector array with a fast gantry rotation time, multidetector computed tomographic (CT) scanners can acquire sections at a faster rate than was previously possible. As a result, multidetector CT permits scanning during multiple specific phases of intravenous contrast enhancement and the acquisition of very thin sections over a large area, allowing the creation of multiplanar reconstructions with high z-axis resolution. The authors present an imaging strategy for the diagnosis and staging of hepatic pathologic conditions that emphasizes the role of multidetector CT. Users must master several scanning parameters to obtain the best image quality. For hepatic CT, it is practical to use relatively narrow collimation, increasing the pitch as needed to cover the entire liver. The choice of reconstruction interval is dependent on the problem for which the study is being performed. Water is recommended as an oral contrast agent for nonaxial reconstructions, since high-attenuation oral contrast agents might degrade them. Appropriate scanning delays for hepatic CT are dependent on the contrast-agent injection strategy used. A triple-pass technique, highlighting the arterial, parenchymal, and portal venous phases of enhancement, is recommended.
引用
收藏
页码:S71 / S80
页数:10
相关论文
共 25 条
[1]   Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[2]   Multidetector-array CT: Once again, technology creates new opportunities [J].
Berland, LL ;
Smith, JK .
RADIOLOGY, 1998, 209 (02) :327-329
[3]   HEPATIC CT ENHANCEMENT .2. ALTERATIONS IN CONTRAST MATERIAL VOLUME AND RATE OF INJECTION WITHIN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM .
RADIOLOGY, 1994, 193 (02) :518-522
[4]   ASSESSMENT OF THE THORACIC AORTA BY SPIRAL CT [J].
COSTELLO, P ;
ECKER, CP ;
TELLO, R ;
HARTNELL, GG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1127-1130
[5]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[6]   Multiphase hepatic CT with a multirow detector CT scanner [J].
Foley, WD ;
Mallisee, TA ;
Hohenwalter, MD ;
Wilson, CR ;
Quiroz, FA ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :679-685
[7]   DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
FORMAN, HP ;
DICROCE, J .
RADIOLOGY, 1993, 187 (02) :327-331
[8]   DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[9]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[10]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18