Noquist:: Reduced field-of-view imaging by direct Fourier inversion

被引:29
作者
Brummer, ME [1 ]
Moratal-Pérez, D
Hong, CY
Pettigrew, RI
Millet-Roig, J
Dixon, WT
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Univ Politecn Valencia, E-46071 Valencia, Spain
[3] Acad Sinica, Inst Biomed Sci, Taipei 115, Taiwan
[4] NIH, Bethesda, MD 20892 USA
[5] GE Co, Global Res, Niskayuna, NY USA
关键词
MRI; image reconstruction; reduced field of view; cardiac imaging; Fast cine imaging;
D O I
10.1002/mrm.10694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel technique called "Noquist" is introduced for the acceleration of dynamic cardiac magnetic resonance imaging (CMRI). With the use of this technique, a more sparsely sampled dynamic image sequence is reconstructed correctly, without Nyquist foldover artifact. Unlike most other reduced field-of-view (rFOV) methods, Noquist does not rely on data substitution or temporal interpolation to reconstruct the dynamic image sequence. The proposed method reduces acquisition time in dynamic MRI scans by eliminating the data redundancy associated with static regions in the dynamic scene. A reduction of imaging time is achieved by a fraction asymptotically equal to the static fraction of the FOV, by omitting acquisition of an appropriate subset of phase-encoding views from a conventional equidistant Cartesian acquisition grid. The theory behind this method is presented along with sample reconstructions from real and simulated data. Noquist is compared with conventional cine imaging by retrospective selection of a reduced. data set from a full-grid conventional image sequence. in addition, a comparison is presented, using real and simulated data, of our technique with an existing rFOV technique that uses temporal interpolation. The experimental results confirm the theory, and demonstrate that Noquist reduces scan time for cine MRI while fully preserving both spatial and temporal resolution, but at the cost of a reduced signal-to-noise ratio (SNR). (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:331 / 342
页数:12
相关论文
共 28 条
  • [1] Bracewell R. N., 1986, FOURIER TRANSFORM IT
  • [2] LOCALLY FOCUSED MRI
    CAO, Y
    LEVIN, DN
    YAO, L
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 858 - 867
  • [3] BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE
    DOYLE, M
    WALSH, EG
    BLACKWELL, GG
    POHOST, GM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 163 - 170
  • [4] HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG
    FEINBERG, DA
    HALE, JD
    WATTS, JC
    KAUFMAN, L
    MARK, A
    [J]. RADIOLOGY, 1986, 161 (02) : 527 - 531
  • [5] IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES
    FOO, TKF
    BERNSTEIN, MA
    AISEN, AM
    HERNANDEZ, RJ
    COLLICK, BD
    BERNSTEIN, T
    [J]. RADIOLOGY, 1995, 195 (02) : 471 - 478
  • [6] Temporal resolution improvement in dynamic imaging
    Fredrickson, JO
    Pelc, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) : 621 - 625
  • [7] THE INFORMATION-CONTENT OF MR IMAGES
    FUDERER, M
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) : 368 - 380
  • [8] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [9] REDUCTION OF FIELD-OF-VIEW FOR DYNAMIC IMAGING
    HU, XP
    PARRISH, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) : 691 - 694
  • [10] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351