In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent - An intravascular ultrasound study

被引:123
作者
Prati, F
Di Mario, C
Moussa, I
Reimers, B
Mallus, MT
Parma, A
Lioy, E
Colombo, A
机构
[1] Ctr Cuore Colombus, I-20145 Milan, Italy
[2] S Camillo Hosp, Catheterizat Lab, Rome, Italy
关键词
ultrasonics; stents; restenosis;
D O I
10.1161/01.CIR.99.8.1011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The aim of this study was to evaluate the relationship between residual plaque burden after coronary stent implantation and the development of late in-stent neointimal proliferation. Methods ann Results-Between January 1996 and May 1997, 50 patients underwent intravascular ultrasound (IVUS) interrogation at 6+/-1.2 months after coronary stent implantation in native coronary arteries. IVUS images were acquired with a motorized pullback, and cross-sectional measurements were performed within the stents at l-mm intervals. The following measurements were obtained: (1) lumen area (LA), (2) stent area (SA), (3) area delimited by the external elastic membrane (EEMA), (4) percent neointimal area calculated as (SA-LA/SA)x100, and (5) percent residual plaque area calculated as (EEMA-SA)/EEMAx100. Volume measurements within the stented segments were calculated by applying Simpson's rule. In the pooled data analysis of 876 cross sections, linear regression showed a significant positive correlation between percent residual plaque area and percent neointimal area (r=0.50, y=45.03+0.29x, P<0.01). There was significant incremental increase in mean percent neointimal area for stepwise increase in percent residual plaque area. Mean percent neointimal area was 16.3+/-10.3% for lesions with a percent residual plaque area of <50% and 27.7+/-11% for lesions with a percent residual plaque area of greater than or equal to 50% (P<0.001). The volumetric analysis showed that the percent residual plaque volume was significantly greater in restenotic lesions compared with nonrestenotic lesions (58.7+/-4.3% versus 51.4+/-5.7%, respectively; P<0.01). Conclusions-Late in-stent neointimal proliferation has a direct correlation with the amount of residual plaque burden after coronary stent implantation, supporting the hypothesis that plaque removal before stent implantation may reduce restenosis.
引用
收藏
页码:1011 / 1014
页数:4
相关论文
共 19 条
[1]   Hoop dreams - Stents without restenosis [J].
Edelman, ER ;
Rogers, C .
CIRCULATION, 1996, 94 (06) :1199-1202
[2]  
*GUID TRIAL INV, 1996, J AM COLL CARDIOL S, V29, pA156
[3]   INTRACORONARY ULTRASOUND IMAGING - CORRELATION OF PLAQUE MORPHOLOGY WITH ANGIOGRAPHY, CLINICAL SYNDROME AND PROCEDURAL RESULTS IN PATIENTS UNDERGOING CORONARY ANGIOPLASTY [J].
HODGSON, JM ;
REDDY, KG ;
SUNEJA, R ;
NAIR, RN ;
LESNEFSKY, EJ ;
SHEEHAN, HM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :35-44
[4]   Chronic arterial responses to stent implantation: A serial intravascular ultrasound analysis of Palmaz-Schatz stents in native coronary arteries [J].
Hoffmann, R ;
Mintz, GS ;
Popma, JJ ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Walsh, C ;
Mackell, P ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1134-1139
[5]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[6]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49
[7]  
HOSOKAWA H, 1996, CIRCULATION, V94, P318
[8]   CORONARY INTIMAL PROLIFERATION AFTER BALLOON INJURY AND STENTING IN SWINE - AN ANIMAL-MODEL OF RESTENOSIS [J].
KARAS, SP ;
GRAVANIS, MB ;
SANTOIAN, EC ;
ROBINSON, KA ;
ANDERBERG, KA ;
KING, SB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :467-474
[9]   Axial plaque redistribution as a mechanism of percutaneous transluminal coronary angioplasty [J].
Mintz, GS ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (05) :427-&
[10]   Arterial remodeling after coronary angioplasty - A serial intravascular ultrasound study [J].
Mintz, GS ;
Popma, JJ ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Wong, SC ;
Hong, MK ;
Kovach, JA ;
Leon, MB .
CIRCULATION, 1996, 94 (01) :35-43