Fast separation of pyrimidine derivatives by capillary electrochromatography on ion-exchange/reversed-phase mixed-mode stationary phases

被引:17
作者
Klampfl, CW
Buchberger, W
Haddad, PR
机构
[1] Johannes Kepler Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
[2] Univ Tasmania, Sch Chem, Separat Sci Grp, Hobart, Tas 7001, Australia
关键词
electrochromatography; stationary phases; mixed-mode chromatography; pyrimidines;
D O I
10.1016/S0021-9673(01)00515-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work describes the use of mixed-mode stationary phases which exhibit both strong ion-exchange (either cation-exchange, SCX, or anion-exchange, SAX) and reversed-phase chromatographic characteristics in capillary electrochromatographic separations of pyrimidine derivatives. Different packing materials, namely C-6, SCX/C-6 and SAX/C-6, were compared and the influence of the composition of the carrier electrolyte (concentration of acetonitrile and pH) on the retention behavior of the selected solutes was investigated. A separation of all eight pyrimidine derivatives could be obtained on a 6.5 cm column packed with the SAX/C-6 stationary phase in less than 3 min, with good peak shapes and efficiencies in the range 39 000 to 81 000 plates per meter. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 34 条
  • [11] Djordjevic NM, 1999, HRC-J HIGH RES CHROM, V22, P599
  • [12] Short-end injection rapid analysis capillary electrochromatography
    Euerby, MR
    Johnson, CM
    Cikalo, M
    Bartle, KD
    [J]. CHROMATOGRAPHIA, 1998, 47 (3-4) : 135 - 140
  • [13] Mixed-mode capillary electrochromatographic separation of anionic analytes
    Hilder, EF
    Macka, M
    Haddad, PR
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (08): : 299 - 303
  • [14] Pressurized-flow anion-exchange capillary electrochromatography using a polymeric ion-exchange stationary phase
    Hilder, EF
    Klampfl, CW
    Haddad, PR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 890 (02) : 337 - 345
  • [15] Use of a mixed-mode packing and voltage tuning for peptide mixture separation in pressurized capillary electrochromatography with an ion trap storage reflectron time of flight mass spectrometer detector
    Huang, PQ
    Jin, XY
    Chen, YJ
    Srinivasan, JR
    Lubman, DM
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (09) : 1786 - 1791
  • [16] KATRIZKY AR, 1984, COMPREHENSIVE HETERO, V3
  • [17] Kitagawa S, 1997, J MICROCOLUMN SEP, V9, P347, DOI 10.1002/(SICI)1520-667X(1997)9:5<347::AID-MCS2>3.0.CO
  • [18] 2-1
  • [19] Investigations on the behaviour of acidic, basic and neutral compounds in capillary electrochromatography on a mixed-mode stationary phase
    Klampfl, CW
    Hilder, EF
    Haddad, PR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 888 (1-2) : 267 - 274
  • [20] Behavior of basic compounds in ion-exchange capillary electrochromatography with low-pH carrier electrolytes
    Klampfl, CW
    Haddad, PR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 277 - 285