Biphasic and monophasic shocks for transthoracic defibrillation: a meta analysis of randomised controlled trials

被引:32
作者
Faddy, SC
Powell, J
Craig, JC
机构
[1] St Vincents Hosp, Dept Cardiol, Darlinghurst, NSW 2010, Australia
[2] Royal N Shore Hosp, Neonatal Intens Care Unit, Sydney, NSW, Australia
[3] Univ Sydney, Dept Publ Hlth & Community Med, Sydney, NSW 2006, Australia
[4] Childrens Hosp, Ctr Kidney Res, Westmead, NSW, Australia
关键词
ventricular fibrillation; defibrillation; cardiopulmonary resuscitation (CPR); meta-analysis;
D O I
10.1016/S0300-9572(03)00077-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Biphasic waveforms are routinely used for implantable defibrillators. These waveforms have been less readily adopted for external defibrillation. This study was performed in order to evaluate the efficacy and harms of biphasic waveforms over monophasic waveforms for the transthoracic defibrillation of patients in ventricular fibrillation (VF) or haemodynamically unstable ventricular tachycardia. Methods: Studies included randomised controlled trials comparing monophasic and biphasic external defibrillation for participants with VF or hemodynamically unstable ventricular tachycardia. Seven trials (1129 patients) were included in the analysis. All trials were conducted during electrophysiology procedures or implantable cardioverter/defibrillator testing. Results: Compared with 200 J monophasic shocks, 200 1 biphasic shocks reduced the risk of post-first shock asystole or persistent VF by 81% (relative risk (RR) 0.19; 95% confidence intervals (CI) 0.06-0.60) for the first shock. Reducing the energy of the biphasic waveform to 115-130 J resulted in similar effectiveness compared with the monophasic waveform at 200 J (RR 1.07, Cl 0.66-1.74). Low energy biphasic shocks produce less myocardial injury than higher energy monophasic shocks as determined by ST segment deflection after shock. Conclusions: Biphasic waveforms defibrillate with similar efficacy at lower energies than standard 200 J monophasic waveforms, and greater efficacy than monophasic shocks of the same energy. Available data suggests that lower delivered energy and voltage result in less post-shock myocardial injury. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 34 条
[1]  
[Anonymous], 1991, Resuscitation, V22, P1
[2]  
AUGOSTINI RS, 1999, PACING CLIN ELECTROP, V22, P827
[3]   TRUNCATED BIPHASIC PULSES FOR TRANSTHORACIC DEFIBRILLATION [J].
BARDY, GH ;
GLINER, BE ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
JONES, GK ;
ANDERSON, J ;
TROUTMAN, C ;
JOHNSON, G .
CIRCULATION, 1995, 91 (06) :1768-1774
[4]   Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation [J].
Bardy, GH ;
Marchlinski, FE ;
Sharma, AD ;
Worley, SJ ;
Luceri, RM ;
Yee, R ;
Halperin, BD ;
Fellows, CL ;
Ahern, TS ;
Chilson, DA ;
Packer, DL ;
Wilber, DJ ;
Mattioni, TA ;
Reddy, R ;
Kronmal, RA ;
Lazzara, R .
CIRCULATION, 1996, 94 (10) :2507-2514
[5]  
CUMPSTON P, 1989, EMERGENCY MED PRINCI, P24
[6]   Cardiac arrest witnessed by emergency medical services personnel: Descriptive epidemiology, prodromal symptoms, and predictors of survival [J].
De Maio, VJ ;
Stiell, IG ;
Wells, GA ;
Spaite, DW .
ANNALS OF EMERGENCY MEDICINE, 2000, 35 (02) :138-146
[7]  
ECHT DS, 1993, PACING CLIN ELECTROP, V16, P1914
[8]  
Gliner Bradford E., 1998, Biomedical Instrumentation and Technology, V32, P631
[9]   Copper deposition on micropatterned electrodes from an industrial acid copper plating bath [J].
Goldbach, S ;
Van den Bossche, B ;
Daenen, T ;
Deconinck, J ;
Lapicque, F .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2000, 30 (01) :1-12
[10]   COMPARISON OF MONOPHASIC AND BIPHASIC DEFIBRILLATING PULSE WAVE-FORMS FOR TRANSTHORACIC CARDIOVERSION [J].
GREENE, HL ;
DIMARCO, JP ;
KUDENCHUK, PJ ;
SCHEINMAN, MM ;
TANG, ASL ;
REITER, MJ ;
ECHT, DS ;
CHAPMAN, PD ;
JAZAYERI, MR ;
CHAPMAN, FW ;
AHMED, M ;
JOHNSON, JL ;
NISKANEN, RA .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (16) :1135-1139