Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy

被引:140
作者
Ding, George X. [1 ]
Duggan, Dennis M.
Coffey, Charles W.
机构
[1] Vanderbilt Univ, Sch Med, Dept Radiat Oncol, Vanderbilt Ingram Canc Ctr, Nashville, TN 37232 USA
关键词
patient dose from CBCT; Monte Carlo simulation; Monte Carlo calibration factor; kV; x-ray dose;
D O I
10.1118/1.2839096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The increased utilization of x-ray imaging in image-guided radiotherapy has dramatically improved the radiation treatment and the lives of cancer patients. Daily imaging procedures, such as cone-beam computed tomography (CBCT), for patient setup may significantly increase the dose to the patient's normal tissues. This study investigates the dosimetry from a kilovoltage (kV) CBCT for real patient geometries. Monte Carlo simulations were used to study the kV beams from a Varian on-board imager integrated into the Trilogy accelerator. The Monte Carlo calculated results were benchmarked against measurements and good agreement was obtained. The authors developed a novel method to calibrate Monte Carlo simulated beams with measurements using an ionization chamber in which the air-kerma calibration factors are obtained from an Accredited Dosimetry Calibration Laboratory. The authors have introduced a new Monte Carlo calibration factor, f(MCcal), which is determined from the calibration procedure. The accuracy of the new method was validated by experiment. When a Monte Carlo simulated beam has been calibrated, the simulated beam can be used to accurately predict absolute dose distributions in the irradiated media. Using this method the authors calculated dose distributions to patient anatomies from a typical CBCT acquisition for different treatment sites, such as head and neck, lung, and pelvis. Their results have shown that, from a typical head and neck CBCT, doses to soft tissues, such as eye, spinal cord, and brain can be up to 8, 6, and 5 cGy, respectively. The dose to the bone, due to the photoelectric effect, can be as much as 25 cGy, about three times the dose to the soft tissue. The study provides detailed information on the additional doses to the normal tissues of a patient from a typical kV CBCT acquisition. The methodology of the Monte Carlo beam calibration developed and introduced in this study allows the user to calculate both relative and absolute absorbed doses. (C) 2008 American Association of Physicists in Medicine. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1135 / 1144
页数:10
相关论文
共 37 条
[1]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[2]  
Ding G, 1995, PIRS, V439
[3]   A study on adaptive IMRT treatment planning using kV cone-beam CT [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Deeley, Matthew ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) :116-125
[4]   Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06) :1595-1615
[5]   Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods [J].
Ding, GX ;
Duggan, DM ;
Coffey, CW .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :2549-2566
[6]   Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator [J].
Ding, GX .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) :1025-1046
[7]  
DING GX, 1995, THESIS CARLETON U OT
[8]   Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: Initial experience [J].
Duggan, Dennis M. ;
Ding, George X. ;
Coffey, Charles W., II ;
Kirby, Wyndee ;
Hallahan, Dennis E. ;
Malcolm, Arnold ;
Lu, Bo .
LUNG CANCER, 2007, 56 (01) :77-88
[9]   Patient dose and image quality from mega-voltage cone beam computed tomography imaging [J].
Gayou, Olivier ;
Parda, David S. ;
Johnson, Mark ;
Miften, Moyed .
MEDICAL PHYSICS, 2007, 34 (02) :499-506
[10]  
Hubbell J. H., 2004, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients, DOI DOI 10.18434/T4D01F