Patient dose and image quality from mega-voltage cone beam computed tomography imaging

被引:70
作者
Gayou, Olivier [1 ]
Parda, David S.
Johnson, Mark
Miften, Moyed
机构
[1] Allegheny Gen Hosp, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[2] Drexel Univ, Coll Med, Pittsburgh, PA 15212 USA
关键词
MV-CBCT; image quality; patient dose; dosimetric measurements;
D O I
10.1118/1.2428407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The evolution of ever more conformal radiation delivery techniques makes the subject of accurate localization of increasing importance in radiotherapy. Several systems can be utilized including kilo-voltage and mega-voltage cone-beam computed tomography (MV-CBCT), CT on rail or helical tomography. One of the attractive aspects of mega-voltage cone-beam CT is that it uses the therapy beam along with an electronic portal imaging device to image the patient prior to the delivery of treatment. However, the use of a photon beam energy in the mega-voltage range for volumetric imaging degrades the image quality and increases the patient radiation dose. To optimize image quality and patient dose in MV-CBCT imaging procedures, a series of dose measurements in cylindrical and anthropomorphic phantoms using an ionization chamber, radiographic films, and thermoluminescent dosimeters was performed. Furthermore, the dependence of the contrast to noise ratio and spatial resolution of the image upon the dose delivered for a 20-cm-diam cylindrical phantom was evaluated. Depending on the anatomical site and patient thickness, we found that the minimum dose deposited in the irradiated volume was 5-9 cGy and the maximum dose was between 9 and 17 cGy for our clinical MV-CBCT imaging protocols. Results also demonstrated that for high contrast areas such as bony anatomy, low doses are sufficient for image registration and visualization of the three-dimensional boundaries between soft tissue and bony structures. However, as the difference in tissue density decreased, the dose required to identify soft tissue boundaries increased. Finally, the dose delivered by MV-CBCT was simulated using a treatment planning system (TPS), thereby allowing the incorporation of MV-CBCT dose in the treatment planning process. The TPS-calculated doses agreed well with measurements for a wide range of imaging protocols. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:499 / 506
页数:8
相关论文
共 17 条
[1]  
BARRETT H H, 1976, Computers in Biology and Medicine, V6, P307, DOI 10.1016/0010-4825(76)90068-8
[2]   In-room CT techniques for image-guided radiation therapy [J].
Charlie, CM ;
Paskalev, K .
MEDICAL DOSIMETRY, 2006, 31 (01) :30-39
[3]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[4]  
Dong L, 2004, INT J RADIAT ONCOL, V60, pS332, DOI 10.1016/S0360-3016(04)01459-2
[5]  
GAYOU O, UNPUB MED PHYS
[6]   Clinical use of electronic portal imaging: Report of AAPM radiation therapy committee Task Group 58 [J].
Herman, MG ;
Balter, JM ;
Jaffray, DA ;
McGee, KP ;
Munro, P ;
Shalev, S ;
Van Herk, M ;
Wong, JW .
MEDICAL PHYSICS, 2001, 28 (05) :712-737
[7]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[8]   On few-view tomographic reconstruction with megavoltage photon beams [J].
Loose, S ;
Leszczynski, KW .
MEDICAL PHYSICS, 2001, 28 (08) :1679-1688
[9]   Image guidance for precise conformal radiotherapy [J].
Mackie, TR ;
Kapatoes, J ;
Ruchala, K ;
Lu, WG ;
Wu, C ;
Olivera, G ;
Forrest, L ;
Tome, W ;
Welsh, J ;
Jeraj, R ;
Harari, P ;
Reckwerdt, P ;
Paliwal, B ;
Ritter, M ;
Keller, H ;
Fowler, J ;
Mehta, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :89-105
[10]   Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system [J].
Miften, M ;
Wiesmeyer, M ;
Monthofer, S ;
Krippner, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :817-833