Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery

被引:51
作者
Abul-Kasim, Kasim [1 ]
Soderberg, Marcus [2 ,3 ]
Selariu, Eufrozina
Gunnarsson, Mikael [2 ,3 ]
Kherad, Mehrsa [4 ]
Ohlin, Acke [4 ]
机构
[1] Lund Univ, Fac Med, Skano Univ Hosp, Diagnost Ctr Imaging & Funct Med,Div Neuroradiol, Malmo, Sweden
[2] Lund Univ, Dept Clin Sci Malmo, Malmo, Sweden
[3] Lund Univ, Fac Med, Skano Univ Hosp, Dept Radiat Phys, Malmo, Sweden
[4] Lund Univ, Fac Med, Skano Univ Hosp, Dept Orthopaed Surg, Malmo, Sweden
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2012年 / 25卷 / 01期
关键词
O-arm; chest phantom; 80; kV; radiation dose; image quality; PEDICLE SCREW INSERTION; GUIDANCE; FLUOROSCOPY; NAVIGATION; PLACEMENT; AGREEMENT; SCOLIOSIS;
D O I
10.1097/BSD.0b013e318211fdea
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design: Retrospective study. Objectives: To optimize the radiation doses and image quality for the cone-beam O-arm surgical imaging system in spinal surgery. Summary of Background: Neurovascular compromise has been reported after screw misplacement during thoracic pedicle screw insertion. The use of O-arm with or without navigation system during spinal surgery has been shown to lower the rate of screw misplacement. The main drawback of such imaging surgical systems is the high radiation exposure. Methods: Chest phantom and cadaveric pig spine were examined on the O-arm with different scan settings: 2 were recommended by the O-arm manufacturer (120 kV/320 mAs, and 120 kV/128 mAs), and 3 low-dose settings (80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs). The radiation doses were estimated by Monte Carlo calculations. Objective evaluation of image quality included interobserver agreement in the measurement of pedicular width in chest phantom and assessment of screw placement in cadaveric pig spine. Results: The effective dose/cm for 120 kV/320 mAs scan was 13, 26, and 69 times higher than those delivered with 80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs scans, respectively. Images with 60 kV/40 mAs were unreliable. Images with 80 kV/80 mAs were considered reliable with good interobserver agreement when measuring the pedicular width (random error 0.38 mm and intraclass correlation coefficient 0.979) and almost perfect agreement when evaluating the screw placement (kappa value 0.86). Conclusions: The radiation doses of the O-arm system can be reduced 5 to 13 times without negative impact on image quality with regard to information required for spinal surgery.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 21 条
[1]
Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis [J].
Abul-Kasim, Kasim ;
Overgaard, Angelica ;
Maly, Pavel ;
Ohlin, Acke ;
Gunnarsson, Mikael ;
Sundgren, Pia C. .
EUROPEAN RADIOLOGY, 2009, 19 (03) :610-618
[2]
[Anonymous], 2007, The 2007 Recommendations of the International Commission on Radiological Protection
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Bongartz G, PROTECTION ECSR
[5]
Evaluation of thyroid shields for reduction of radiation exposure to orthopaedic surgeons [J].
Dewey, P ;
Incoll, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (09) :635-636
[6]
F. X. Masse Associates Inc, 2009, MEDTR NAV DOS REP ME
[7]
Does computer-assisted spine surgery reduce intraoperative radiation doses? [J].
Gebhard, Florian T. ;
Kraus, Michael D. ;
Schneider, Eugen ;
Liener, Ulrich C. ;
Kinzl, Lothar ;
Arand, Markus .
SPINE, 2006, 31 (17) :2024-2027
[8]
BREAST-CANCER IN WOMEN WITH SCOLIOSIS EXPOSED TO MULTIPLE DIAGNOSTIC X-RAYS [J].
HOFFMAN, DA ;
LONSTEIN, JE ;
MORIN, MM ;
VISSCHER, W ;
HARRIS, BSH ;
BOICE, JD .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1989, 81 (17) :1307-1312
[9]
Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine [J].
Jones, DPG ;
Robertson, PA ;
Lunt, B ;
Jackson, SA .
SPINE, 2000, 25 (12) :1538-1541
[10]
Kim JM, 2007, SEMIN SPINE SURG, V19, P78