Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine

被引:133
作者
Jones, DPG
Robertson, PA
Lunt, B
Jackson, SA
机构
[1] Auckland Hosp, Dept Orthopaed Surg, Auckland 1001, New Zealand
[2] Christchurch Hosp, Christchurch, New Zealand
[3] Dunedin Hosp, Dunedin, New Zealand
关键词
fluoroscopy; lumbosacral region; radiation protection; spinal fusion;
D O I
10.1097/00007632-200006150-00013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An experimental model to assess radiation exposure during lumbar pedicle screw insertion. Objectives. To measure skin (patient) and scatter (surgeon) doses of radiation during lumbar spine fluoroscopy to assess safety of the procedure for both the surgeon and patient and determine best practice; Summary of Background Data. Fluoroscopy assists with accuracy of pedicle screw placement, yet the optimal technique of C-arm use and risk to both patient and operating room staff from radiation exposure are unknown. Methods. Entry- and scatter-dose recordings were made using a digital dosimeter while screening an anthropomorphic phantom prone on a radiolucent operating table. The source was positioned both superiorly and inferiorly with the height varied in the latter orientation to create a working space under the C-arm. The senior author's fluoroscopy records were reviewed in 140 consecutive cases. Results. In a series of 140 patients who underwent pedicle screw fixation, the fluoroscopy time was 1.4 minutes per case or 0.33 minutes per screw. In the source-superior position, the effective dose received by the patient was approximately 2.3 mSv per case. In the source-inferior position with a working space of 300 mm, the effective dose was 6.8 mSv. Scatter dose to the surgeon was higher in the source-superior position but was still less than 10% of recommended limits for the hand, thyroid, and eyes. Conclusions. The source-superior position is the preferred position for pedicle screw screening if a working space is required. Patient exposure is minimized, and surgeon dose is well within current recommendations.
引用
收藏
页码:1538 / 1541
页数:4
相关论文
共 14 条
[1]
Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[2]
Evaluation of thyroid shields for reduction of radiation exposure to orthopaedic surgeons [J].
Dewey, P ;
Incoll, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (09) :635-636
[3]
ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[4]
The Graf ligamentoplasty procedure - Comparison with posterolateral fusion in the management of low back pain [J].
Hadlow, SV ;
Fagan, AB ;
Hillier, TM ;
Fraser, RD .
SPINE, 1998, 23 (10) :1172-1179
[5]
HYNES DE, 1992, J BONE JOINT SURG BR, V74, P332
[6]
International Commission on Radiological Protection, 1991, ICRP PUBL
[7]
JACKSON SA, 2000, J BONE JT SURG S1, V82, P32
[8]
Radiation use in the orthopaedic theatre: A prospective audit [J].
Jones, DG ;
Stoddart, J .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (11) :782-784
[9]
PLACEMENT OF TRANSPEDICULAR VERTEBRAL SCREWS CLOSE TO ANTERIOR VERTEBRAL CORTEX - DESCRIPTION OF METHODS [J].
KRAG, MH ;
VANHAL, ME ;
BEYNNON, BD .
SPINE, 1989, 14 (08) :879-883
[10]
SJOSTROM L, 1993, J SPINAL DISORD, V6, P225