Constant-distance mode AC-SECM for the visualisation of corrosion pits

被引:66
作者
Eckhard, Kathrin
Etienne, Mathieu
Schulte, Albert
Schuhmann, Wolfgang
机构
[1] Ruhr Univ Bochum, D-4630 Bochum, Germany
[2] Univ Nancy 1, CNRS, Lab Chim Phys & Microbiol Environm, F-54600 Nancy, France
[3] Univ W Indies, Fac Agr Sci, Dept Chem, St Augustine, Trinidad Tobago
关键词
corrosion; 316; TiSS; stainless steel; scanning electrochemical microscopy; AC-SECM; alternating current; direct mode; constant-distance mode; shear force;
D O I
10.1016/j.elecom.2007.03.035
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The local visualisation of corrosion pits has so far failed to convincingly prove the advantage of scanning microscopy in overcoming Abbey's Limit. Thus, for imaging pit initiation and instant pit growth the resolution of the methods used for detecting the related changes in local electrochemical activity has to be significantly improved. Progress into this direction has been achieved by combining shear force based constant-distance mode scanning electrochemical microscopy (SECM) with the alternating current mode of this technique (AC-SECM). A very small corrosion pit was generated by inducing active corrosion underneath an accurately positioned 5 pm diameter Pt disk SECM tip that served as counter electrode in the direct mode of SECM. Before and after pit initiation, constant-distance mode AC-SECM images were recorded and subsequently used to identify the area of broken passivity. The results demonstrate the feasibility of the suggested approach to image actively corroding sites with overall dimensions of only a few micrometers. Combination of constant-distance scanning with AC-SECM is an important prerequisite for further improving spatial resolution by employing smaller-diameter micro- or even nano-electrodes as SECM tips. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1793 / 1797
页数:5
相关论文
共 33 条
[1]   Impedance feedback control for scanning electrochemical microscopy [J].
Alpuche-Aviles, MA ;
Wipf, DO .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4873-4881
[2]   Application of localised electrochemical techniques to study kinetics of initiation and propagation during pit growth [J].
Annergren, I ;
Zou, F ;
Thierry, D .
ELECTROCHIMICA ACTA, 1999, 44 (24) :4383-4393
[3]   Local electrochemical impedance spectroscopy applied to the corrosion behavior of an AZ91 magnesium alloy [J].
Baril, G ;
Blanc, C ;
Keddam, M ;
Pébère, N .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (10) :B488-B493
[4]   Application of the scanning electrochemical microscope to the examination of organic coatings on metallic substrates [J].
Bastos, AC ;
Simoes, AM ;
González, S ;
González-García, Y ;
Souto, RM .
PROGRESS IN ORGANIC COATINGS, 2005, 53 (03) :177-182
[5]   In situ investigation of localized corrosion of aluminum alloys in chloride solution using integrated EC-AFM/SECM techniques [J].
Davoodi, A ;
Pan, J ;
Leygraf, C ;
Norgren, S .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2005, 8 (06) :B21-B24
[6]   Alternating current impedance imaging of membrane pores using scanning electrochemical microscopy [J].
Ervin, EN ;
White, HS ;
Baker, LA .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5564-5569
[7]   High resolution constant-distance mode alternating current scanning electrochemical microscopy (AC-SECM) [J].
Etienne, M ;
Schulte, A ;
Schuhmann, W .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (03) :288-293
[8]   Development of a coupled SECM-EQCM technique for the study of pitting corrosion on iron [J].
Gabrielli, C ;
Joiret, S ;
Keddam, M ;
Perrot, H ;
Portail, N ;
Rousseau, P ;
Vivier, V .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (03) :B68-B74
[9]   Scanning electrochemical microscopy imaging by means of high-frequency impedance measurements in feedback mode [J].
Gabrielli, C ;
Huet, F ;
Keddam, M ;
Rousseau, P ;
Vivier, V .
JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (31) :11620-11626
[10]   Imaging metastable pits on austenitic stainless steel in situ at the open-circuit corrosion potential [J].
González-García, Y ;
Burstein, GT ;
González, S ;
Souto, RM .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (07) :637-642