Development of a one-step immunochromatographic strip test using gold nanoparticles for the rapid detection of Salmonella typhi in human serum

被引:109
作者
Preechakasedkit, Pattarachaya [2 ]
Pinwattana, Kulwadee [3 ]
Dungchai, Wijitar [4 ]
Siangproh, Weena [5 ]
Chaicumpa, Wanpen [6 ]
Tongtawe, Pongsri [7 ]
Chailapakul, Orawon [1 ,8 ]
机构
[1] Chulalongkorn Univ, Innovat Electrochem & Opt Analyt Syst Res Unit, Fac Sci, Dept Chem, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Program Biotechnol, Fac Sci, Bangkok 10330, Thailand
[3] Pibulsongkram Rajabhat Univ, Fac Sci & Technol, Dept Chem, Phitsanulok 65000, Thailand
[4] King Mongkuts Univ Technol Thonburi, Fac Sci, Dept Chem, Bangkok 10140, Thailand
[5] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok 10110, Thailand
[6] Mahidol Univ, Fac Med, Dept Parasitol, Siriraj Hosp, Bangkok 10700, Thailand
[7] Thammasat Univ, Fac Allied Hlth Sci, Pathum Thani 12120, Thailand
[8] Chulalongkorn Univ, Ctr Excellence Petr Petrochem & Adv Mat, Bangkok 10330, Thailand
关键词
Salmonella typhi; Immunochromatographic strip test; Gold nanoparticles; ALKALINE-PHOSPHATASE; ENZYME-IMMUNOASSAY; COLLOIDAL GOLD; WATER SAMPLES; LABEL; FEVER; PROBE; CONJUGATE; PATHOGENS; SUBSTRATE;
D O I
10.1016/j.bios.2011.10.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi 0901 and antibody of S. typhi 0901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi 0901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14 x 10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88 x 10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:562 / 566
页数:5
相关论文
共 30 条
[1]
Laboratory evaluation of a simple and rapid latex agglutination assay for the serodiagnosis of typhoid fever [J].
Abdoel, Theresia H. ;
Pastoor, Rob ;
Smits, Henk L. ;
Hatta, Mochammad .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2007, 101 (10) :1032-1038
[2]
Label-free detection of multiple bacterial pathogens using light-scattering sensor [J].
Banada, Padmapriya P. ;
Huff, Karleigh ;
Bae, Euiwon ;
Rajwa, Bartek ;
Aroonnual, Amornrat ;
Bayraktar, Bulent ;
Adil, Abrar ;
Robinson, J. Paul ;
Hirleman, E. Daniel ;
Bhunia, Arun K. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1685-1692
[3]
Boever J.D., 1995, ANAL CHIM ACTA, V303, P143
[4]
Carlo M.D., 1996, ANAL CHIM ACTA, V336, P167
[5]
Chaicumpa W, 1995, ASIAN PAC J ALLERGY, V13, P159
[6]
An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label [J].
Chu, X ;
Fu, X ;
Chen, K ;
Shen, GL ;
Yu, RQ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1805-1812
[7]
Salmonella typhi determination using voltammetric amplification of nanoparticles: A highly sensitive strategy for metalloimmunoassay based on a copper-enhanced gold label [J].
Dungchai, Wijitar ;
Siangproh, Weena ;
Chaicumpa, Wanpen ;
Tongtawe, Pongsri ;
Chailapakul, Orawon .
TALANTA, 2008, 77 (02) :727-732
[8]
Typhoid fever vaccines: Systematic review and meta-analysis of randomised controlled trials [J].
Fraser, Abigail ;
Paul, Mical ;
Goldberg, Elad ;
Acosta, Camilo J. ;
Leibovici, Leonard .
VACCINE, 2007, 25 (45) :7848-7857
[9]
Gold nanoparticles in delivery applications [J].
Ghosh, Partha ;
Han, Gang ;
De, Mrinmoy ;
Kim, Chae Kyu ;
Rotello, Vincent M. .
ADVANCED DRUG DELIVERY REVIEWS, 2008, 60 (11) :1307-1315
[10]
Development of zeptomole and attomolar detection sensitivity of biotin-peptide using a dot-blot goldnanoparticle immunoassay [J].
Hou, Shao-Yi ;
Chen, Hsi-Kuei ;
Cheng, Hsu-Chieh ;
Huang, Chun-Yen .
ANALYTICAL CHEMISTRY, 2007, 79 (03) :980-985