Chiral resolution of enantiomeric steroids by high-performance liquid chromatography on amylose tris(3,5-dimethylphenylcarbamate) under reversed-phase conditions

被引:39
作者
Kummer, M
Werner, G
机构
[1] Jenapharm Gmbh & Co KG, Div Res & Dev, D-07745 Jena, Germany
[2] Univ Leipzig, Dept Analyt Chem, D-04103 Leipzig, Germany
关键词
enantiomer separation; amylose tris(3,5-dimethylphenylcarbamate) stationary phases; chiral stationary phases; LC; steroids; estradiol;
D O I
10.1016/S0021-9673(98)00719-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) was used under reversed-phase conditions for the: chiral separation of 26 steroids. It was found that the chiral separation behavior of Chiralpak AD under reversed-phase conditions differs clearly from those under normal-phase conditions thereby extending the range of application of this chiral stationary phase. The substitution of methanol for acetonitrile in the aqueous eluent did not grossly change the chiral separation behavior. The enantioselectivity under reversed-phase conditions is strongly dependent on the water concentration in the eluent up to 10%. The influence of the temperature on the chiral separation is discussed from a practical point of view. A HPLC method for the quantification of the unnatural enantiomer of estradiol in drug substances applying Chiralpak AD under reversed-phase conditions was developed and successfully validated. (C) 1998 Elsevier Science BN. AU rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 25 条
[2]  
[Anonymous], 1994, PRACTICAL APPROACH C, DOI DOI 10.1002/bit.20729
[3]   OPTICAL ISOMER SEPARATION BY LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :A84-&
[4]   CYCLODEXTRIN CHIRAL STATIONARY PHASES FOR LIQUID-CHROMATOGRAPHIC SEPARATIONS OF DRUG STEREOISOMERS [J].
BERTHOD, A ;
JIN, HL ;
BEESLEY, TE ;
DUNCAN, JD ;
ARMSTRONG, DW .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (02) :123-130
[5]  
Blom Y., 1993, PHARMEUROPA, V5, P381
[6]   SOME ASPECTS OF THE SELECTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE SEPARATION OF CHIRAL COMPOUNDS IN PHARMACEUTICAL ANALYSIS [J].
GAZDAG, M ;
SZEPESI, G ;
MIHALYFI, K .
JOURNAL OF CHROMATOGRAPHY, 1988, 450 (02) :145-155
[7]   ALPHA-CYCLODEXTRINS, BETA-CYCLODEXTRINS AND GAMMA-CYCLODEXTRINS AS MOBILE PHASE ADDITIVES IN THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF ENANTIOMERIC COMPOUNDS .1. SEPARATION OF OPTICAL ISOMERS OF D,L-NORGESTREL [J].
GAZDAG, M ;
SZEPESI, G ;
HUSZAR, L .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (01) :128-135
[8]   SEPARATION OF ISOMERIC COMPOUNDS AS CYCLODEXTRIN INCLUSION COMPLEXES ON A CYANOPROPYLSILICA STATIONARY PHASE [J].
GAZDAG, M ;
SZEPESI, G ;
HUSZAR, L .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :227-234
[9]   PLANAR CHIRAL SYSTEMS .1. OPTICAL RESOLUTION OF [2.2]PARACYCLOPHANES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON TRIS(3,5-DIMETHYLPHENYLCARBAMATES) OF CELLULOSE AND AMYLOSE [J].
HOPF, H ;
GRAHN, W ;
BARRETT, DG ;
GERDES, A ;
HILMER, J ;
HUCKER, J ;
OKAMOTO, Y ;
KAIDA, Y .
CHEMISCHE BERICHTE, 1990, 123 (04) :841-845
[10]  
INOUE K, 1996, 8 INT S CHIR DISCR E