Temporal changes of coronary artery plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold

被引:14
作者
Brugaletta, Salvatore [1 ]
Garcia-Garcia, Hector M. [1 ,2 ]
Garg, Scot [1 ]
Gomez-Lara, Josep [1 ]
Diletti, Roberto [1 ]
Onuma, Yoshinobu [1 ]
van Geuns, Robert Jan [1 ]
McClean, Dougal [3 ]
Dudek, Dariusz [4 ]
Thuesen, Leif [5 ]
Chevalier, Bernard [6 ]
Windecker, Stephan [7 ]
Whitbourn, Robert [8 ]
Dorange, Cecile [9 ]
Miquel-Hebert, Karine [9 ]
Sudhir, Krishnankutty [9 ]
Ormiston, John A. [10 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Cardialysis BV, Rotterdam, Netherlands
[3] Chrischurch Hosp, Chrischurch, New Zealand
[4] Jagiellonian Univ, Krakow, Poland
[5] Skejby Sygehus, DK-8200 Aarhus, Denmark
[6] Inst Cardiovasc Paris Sud, Massy, France
[7] Univ Hosp Bern, CH-3010 Bern, Switzerland
[8] St Vincents Hosp, Fitzroy, Vic 3065, Australia
[9] Abbott Vasc, Diegem, Belgium
[10] Auckland City Hosp, Dept Cardiol, Auckland, New Zealand
关键词
Bioresorbable vascular scaffold; Coronary plaque; IVUS-VH; Everolimus; HISTOLOGY INTRAVASCULAR ULTRASOUND; RADIOFREQUENCY DATA-ANALYSIS; STENT SYSTEM; ATHEROSCLEROTIC PLAQUES; IMPLANTATION; MACROPHAGES; AUTOPHAGY; RELEASE; HUMANS; ABSORB;
D O I
10.1007/s10554-010-9724-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 +/- A 1.93 mm(2) vs. 3.19 +/- A 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 +/- A 4.07 mm(2) vs. 14.76 +/- A 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 +/- A 0.70 mm(2) vs. 1.21 +/- A 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 +/- A 0.79 mm(2) vs. 1.15 +/- A 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.
引用
收藏
页码:859 / 866
页数:8
相关论文
共 25 条
[11]   Everolimus-induced rnTOR inhibition selectively depletes macrophages in atherosclerotic plaques by autophagy [J].
Martinet, Wim ;
Verheye, Stefan ;
De Meyer, Guido R. Y. .
AUTOPHAGY, 2007, 3 (03) :241-244
[12]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323
[13]   Coronary plaque classification with intravascular ultrasound radiofrequency data analysis [J].
Nair, A ;
Kuban, BD ;
Tuzcu, EM ;
Schoenhagen, P ;
Nissen, SE ;
Vince, DG .
CIRCULATION, 2002, 106 (17) :2200-2206
[14]  
ONUMA Y, CIRCULATION IN PRESS
[15]   MAHOROBA, first-in-man study: 6-month results of a biodegradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses [J].
Onuma, Yoshinobu ;
Serruys, Patrick ;
den Heijer, Peter ;
Joesoef, Kaiyum Sheik ;
Duckers, Henricus ;
Regar, Evelyn ;
Kukreja, Neville ;
Tanimoto, Shuzou ;
Garcia-Garcia, Hector M. ;
van Beusekom, Heleen ;
van der Giessen, Willem ;
Nishide, Takuji .
EUROPEAN HEART JOURNAL, 2009, 30 (12) :1477-1485
[16]   A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial [J].
Ormiston, John A. ;
Serruys, Patrick W. ;
Regar, Evelyn ;
Dudek, Dariusz ;
Thuesen, Leif ;
Webster, Mark W. I. ;
Onuma, Yoshinobu ;
Garcia-Garcia, Hector M. ;
McGreevy, Robert ;
Veldhof, Susan .
LANCET, 2008, 371 (9616) :899-907
[17]   Coronary artery remodelling is related to plaque composition [J].
Rodriguez-Granillo, GA ;
Serruys, PW ;
Garcia-Garcia, HM ;
Aoki, J ;
Valgimigli, M ;
van Mieghem, CAG ;
McFadden, E ;
de Jaegere, PPT ;
de Feyter, P .
HEART, 2006, 92 (03) :388-391
[18]   Reproducibility of intravascular ultrasound radiofrequency data analysis:: implications for the design of longitudinal studies [J].
Rodriguez-Granillo, Gaston A. ;
Vaina, Sophia ;
Garcia-Garcia, Ctor M. ;
Valgimigli, Marco ;
Duckers, Eric ;
van Geuns, Robert J. ;
Regar, Evelyn ;
van der Giessen, William J. ;
Bressers, Marco ;
Goedhart, Dick ;
Morel, Marie-Angele ;
de Feyter, Pim J. ;
Serruys, Patrick W. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (05) :621-631
[19]   IVUS Radiofrequency Analysis in the Evaluation of the Polymeric Struts of the Bioabsorbable Everolimus-Eluting Device During the Bioabsorption Process [J].
Sarno, Giovanna ;
Onuma, Yoshinobu ;
Garcia, Hector M. Garcia ;
Garg, Scot ;
Regar, Evelyn ;
Thuesen, Leif ;
Dudek, Dariusz ;
Veldhof, Susan ;
Dorange, Cecile ;
Ormiston, John A. ;
Serruys, Patrick W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (06) :914-918
[20]   A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods [J].
Serruys, Patrick W. ;
Ormiston, John A. ;
Onuma, Yoshinobu ;
Regar, Evelyn ;
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Nieman, Koen ;
Bruining, Nico ;
Dorange, Cecile ;
Miquel-Hebert, Karine ;
Veldhof, Susan ;
Webster, Mark ;
Thuesen, Leif ;
Dudek, Dariusz .
LANCET, 2009, 373 (9667) :897-910