Electromagnetic navigation bronchoscopy-guided fiducial placement for robotic stereotactic radiosurgery of lung tumors - A feasibility study

被引:123
作者
Anantham, Devanand
Feller-Kopman, David
Shanmugham, Lakshmi N.
Bennan, Stuart M.
DeCamp, Malcolm M.
Gangadharan, Sidhu P.
Eberhardt, Ra
Herth, Felix
Ernst, Armin
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Boston, MA 02215 USA
[2] Univ Heidelberg, Thoraxklin, Dept Pneumol & Crit Care Med, Heidelberg, Germany
关键词
cyberknife; electromagnetic navigation bronchoscopy; fiducial; lung cancer; robotic stereotactic radiosurgery;
D O I
10.1378/chest.07-0522
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Background: Stereotactic radiosurgery (Cyberknife; Accuray Incorporated; Sunnyvale, CA) is a treatment option for patients who are medically unfit to undergo lung tumor resection. For precise tumor ablation, the Cyberknife requires fiducial marker placement in or near the target tumor. Fiducial placement under transthoracic CT guidance is associated with a high risk of iatrogenic pneumothorax. Electromagnetic navigation bronchoscopy (ENB) may offer a less morbid alternative to accurately deploy fiducials to bronchoscopically invisible peripheral lung lesions. Objective: Open-label, feasibility study to assess fiducial placement in peripheral lung tumors by ENB. Method: Consecutive patients with peripheral lung tumors and who were evaluated to be nonsurgical candidates underwent fiducial placement under ENB. This procedure was considered successful if fiducials were placed in or near the tumors and remained in place without migration for radiosurgery to proceed. The need for alternative or additional intrathoracic fiducial placement was documented as procedure failure. Results: A total of 39 fiducials markers were successfully deployed in eight of nine patients (89%). Of these eight successful cases, seven had fiducials placed directly within the tumor (88%). At Cyberknife planning, 7 to 10 days after fiducial placement, 35 of 39 fiducial markers (90%) were still in place and were adequate to allow radiosurgery to proceed. No immediate bronchoscopic complications were observed. One patient had a COPD exacerbation. Another patient returned within 1 day with transient, self-limiting fever. Conclusions: ENB can be used to deploy fiducial markers for Cyberknife radiosurgery of lung tumors safely and accurately without the complications associated with transthoracic placement.
引用
收藏
页码:930 / 935
页数:6
相关论文
共 15 条
[1]
*ACC INC, 2005, CYBERKNIFE SYST PAT, P16
[2]
Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054
[3]
Bronchoscopic Biopsy of Peripheral Lung Lesions Under Electromagnetic Guidance [J].
Becker, Heinrich D. ;
Herth, Felix ;
Ernst, Armin ;
Schwarz, Yehuda .
JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2005, 12 (01) :9-13
[4]
CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[5]
Electromagnetic navigation diagnostic bronchoscopy - A prospective study [J].
Gildea, Thomas R. ;
Mazzone, Peter J. ;
Karnak, Demet ;
Meziane, Moulay ;
Mehta, Atul C. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (09) :982-989
[6]
Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy [J].
Harada, T ;
Shirato, H ;
Ogura, S ;
Oizumi, S ;
Yamazaki, K ;
Shimizu, S ;
Onimaru, R ;
Miyasaka, K ;
Nishimura, M ;
Dosaka-Akita, H .
CANCER, 2002, 95 (08) :1720-1727
[7]
Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy [J].
Imura, M ;
Yamazaki, K ;
Shirato, H ;
Onimaru, R ;
Fujino, M ;
Shimizu, S ;
Harada, T ;
Ogura, S ;
Dosaka-Akita, H ;
Miyasaka, K ;
Nishimura, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (05) :1442-1447
[8]
Embolotherapy of pulmonary arteriovenous malformations: Long-term results in 112 patients [J].
Mager, JJ ;
Overtoom, TTC ;
Blauw, H ;
Lammers, JWJ ;
Westermann, CJJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (05) :451-456
[9]
Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife:: Marker placement and early results [J].
Nuyttens, J. J. ;
Prevost, J. -B. ;
Praag, J. ;
Hoogeman, M. ;
Van Klaveren, R. J. ;
Levendag, P. C. ;
Pattynama, P. M. T. .
ACTA ONCOLOGICA, 2006, 45 (07) :961-965
[10]
Embolotherapy of pulmonary arteriovenous malformations: Efficacy of platinum versus stainless steel coils [J].
Prasad, V ;
Chan, RP ;
Faughnan, ME .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (02) :153-160