Can spectral computed tomography imaging improve the differentiation between malignant and benign pulmonary lesions manifesting as solitary pure ground glass, mixed ground glass, and solid nodules?

被引:63
作者
Chen, Mai-Lin [1 ]
Li, Xiao-Ting [1 ]
Wei, Yi-Yuan [1 ]
Qi, Li-Ping [1 ]
Sun, Ying-Shi [1 ]
机构
[1] Peking Univ, Key Lab Carcinogenesis & Translat Res, Minist Educ Beijing, Dept Radiol,Canc Hosp & Inst, 52 Fucheng Rd, Beijing 100142, Peoples R China
基金
北京市自然科学基金;
关键词
Computed tomography; solitary pulmonary nodule; spectral CT; DUAL-ENERGY CT; LUNG CANCERS; ENHANCEMENT;
D O I
10.1111/1759-7714.12937
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Background This study quantitatively assessed the efficacy of spectral computed tomography (CT) imaging parameters for differentiating the malignancy and benignity of solitary pulmonary nodules (SPNs) manifesting as ground glass nodules (GGNs) and solid nodules (SNs). Methods The study included 114 patients with SPNs (61 GGNs, and 53 SNs) who underwent CT plain and enhanced scans in the arterial (a) and venous (v) phases using the spectral imaging mode. The spectral CT imaging parameters included: iodine concentrations (IC) of lesions in the arterial (ICLa) and venous (ICLv) phases; normalized IC (NICa/NICv, normalized to the IC in the aorta); the slope of the spectral Hounsfield unit (HU) curve (lambda HUa/lambda HUv); and monochromatic CT number (CT40keVa/v, CT70keVa/v) enhancement on 40 and 70 keV images. The two-sample Mann-Whitney U test was used to compare quantitative parameters between malignant and benign SPNs, SNs, and GGNs. Results Pathology revealed 75 lung cancer cases, 3 metastatic nodules, 14 benign nodules, and 22 inflammatory nodules. Among the 53 SNs there were 37 malignant and 16 benign nodules. Among the 61 GGNs there were 41 malignant and 20 benign nodules. Overall, the CT40keVa, lambda HUa, CT40keVv, lambda HUv, and ICLv of benign SPNs were all greater than those of malignant SPNs (all P < 0.05). For GGNs, CT40keVa/v, CT70keVa/v, lambda HUa/lambda HUv, and ICLv of malignant GGNs were all lower than those of benign GGNs. Conclusion Spectral CT imaging is a more promising method for distinguishing malignant from benign nodules, especially in nodules manifesting as GGNs in contrast-enhanced scanning.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 23 条
[1]
Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience [J].
Chae, Eun Jin ;
Song, Jae-Woo ;
Seo, Joon Beom ;
Krauss, Bernhard ;
Jang, Yu Mi ;
Song, Koun-Sik .
RADIOLOGY, 2008, 249 (02) :671-681
[2]
Dual-Energy CT: Oncologic Applications [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Bellini, Davide ;
Ayuso, Carmen ;
Laghi, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S98-S105
[3]
Dynamic contrast-enhanced CT in suspected lung cancer: quantitative results [J].
Harders, S. W. ;
Madsen, H. H. ;
Nellemann, H. M. ;
Rasmussen, T. R. ;
Thygesen, J. ;
Hager, H. ;
Andersen, N. T. ;
Rasmussen, F. .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031)
[4]
Functional CT imaging techniques for the assessment of angiogenesis in lung cancer [J].
Henzler, Thomas ;
Shi, Jingyun ;
Jafarov, Hashim ;
Schoenberg, Stefan O. ;
Manegold, Christian ;
Fink, Christian ;
Schmid-Bindert, Gerald .
TRANSLATIONAL LUNG CANCER RESEARCH, 2012, 1 (01) :78-83
[5]
Differentiation of Lung Cancers From Inflammatory Masses with Dual-Energy Spectral CT Imaging [J].
Hou, Wei Shu ;
Wu, Hua Wei ;
Yin, Yan ;
Cheng, Jie Jun ;
Zhang, Qing ;
Xu, Jian Rong .
ACADEMIC RADIOLOGY, 2015, 22 (03) :337-344
[6]
Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[7]
Dual-energy CT revisited with multidetector CT: review of principles and clinical applications [J].
Karcaaltincaba, Musturay ;
Aktas, Aykut .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03) :181-194
[8]
Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies [J].
Kawai, Tatsuya ;
Shibamoto, Yuta ;
Hara, Masaki ;
Arakawa, Toshinao ;
Nagai, Keiichi ;
Ohashi, Kazuya .
ACADEMIC RADIOLOGY, 2011, 18 (06) :682-689
[9]
A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy [J].
Kim, Hyungjin ;
Park, Chang Min ;
Lee, Sang Min ;
Lee, Hyun-Ju ;
Goo, Jin Mo .
KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (04) :683-691
[10]
Additional value of dual-energy CT to differentiate between benign and malignant mediastinal tumors: An initial experience [J].
Lee, Seung Hyun ;
Hur, Jin ;
Kim, Young Jin ;
Lee, Hye-Jeong ;
Hong, Yoo Jin ;
Choi, Byoung Wook .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) :2043-2049