Pulse oximetry in sickle cell anemia

被引:34
作者
Fitzgerald, RK
Johnson, A
机构
[1] Childrens Mem Hosp, Div Pediat Emergency Med, Dept Pediat, Chicago, IL 60614 USA
[2] Northwestern Univ, Sch Med, Dept Pediat, Chicago, IL 60611 USA
关键词
sickle cell disease; pulse oximetry; blood gas monitoring; cooximetry; arterial blood gas; oxygen dissociation curve; methemoglobin; carboxyhemoglobin; acute chest syndrome; oximetry;
D O I
10.1097/00003246-200109000-00025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives. To determine whether pulse oximetry is accurate and if it correlates with arterial blood gas saturation in pediatric patients with sickle cell anemia. Design: Prospective, comparative study using a convenience sample of patients with sickle cell anemia who had simultaneous arterial blood gas sampling and pulse oximetry. Setting, Children's Memorial Hospital, a large tertiary care pediatric hospital in Chicago, IL. Patients selected from the emergency department and the pediatric intensive care unit. Patients: Twenty-four consecutive patients with sickle cell anemia who had simultaneous arterial blood gas sampling and pulse oximetry. Measurements and Main Results: Twenty-four patients had a total of 70 simultaneous pulse oximeter and blood gas pair samples. Each patient's initial pulse oximeter/blood gas pair was used in the statistical analysis. Three patients had venous Samples and were excluded from comparison, leaving 21 arterial blood gas/pulse oximeter pairs for analysis. The pulse oximeter correlated well with the cooximeter-measured arterial saturation (r(2) = .74). The pulse oximeter significantly underestimated saturation by a mean of -1.6% (95% confidence interval, -0.3 to -3; p = .03). Conclusions: Pulse oximetry correlates well with cooximeter-measured saturation in patients with sickle cell anemia. Pulse oximetry significantly underestimates true arterial saturation, but the bias is clinically insignificant. Pulse oximetry can be used reliably to estimate the arterial oxygen saturation in patients with sickle cell anemia.
引用
收藏
页码:1803 / 1806
页数:4
相关论文
共 18 条
[1]   THE EFFECT OF CARBON-MONOXIDE INHALATION ON PULSE OXIMETRY AND TRANS-CUTANEOUS PO2 [J].
BARKER, SJ ;
TREMPER, KK .
ANESTHESIOLOGY, 1987, 66 (05) :677-679
[2]   RANGE OF ACCURACY OF 2 WAVELENGTH OXIMETRY [J].
CHAPMAN, KR ;
LIU, FLW ;
WATSON, RM ;
REBUCK, AS .
CHEST, 1986, 89 (04) :540-542
[3]   Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis [J].
Comber, JT ;
Lopez, BL .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (01) :16-18
[4]   COMPARISON OF OXYGENATION MEASUREMENTS IN PEDIATRIC-PATIENTS DURING SICKLE-CELL CRISES [J].
CRAFT, JA ;
ALESSANDRINI, E ;
KENNEY, LB ;
KLEIN, B ;
BRAY, G ;
LUBAN, NLC ;
MEEK, R ;
NADKARNI, VM .
JOURNAL OF PEDIATRICS, 1994, 124 (01) :93-95
[5]   PULSE OXIMETRY IN PEDIATRIC INTENSIVE-CARE - COMPARISON WITH MEASURED SATURATIONS AND TRANS-CUTANEOUS OXYGEN-TENSION [J].
FANCONI, S ;
DOHERTY, P ;
EDMONDS, JF ;
BARKER, GA ;
BOHN, DJ .
JOURNAL OF PEDIATRICS, 1985, 107 (03) :362-366
[6]  
Golden C, 1998, Curr Opin Hematol, V5, P89
[7]   Determination of hemoglobin saturation in patients with acute sickle chest syndrome - A comparison of arterial blood cases and pulse oximetry [J].
Kress, JP ;
Pohlman, AS ;
Hall, JB .
CHEST, 1999, 115 (05) :1316-1320
[8]  
Mackenzie N, 1985, J Clin Monit, V1, P156, DOI 10.1007/BF02832255
[9]   Accuracy of pulse oximetry in sickle cell disease [J].
Ortiz, FO ;
Aldrich, TK ;
Nagel, RL ;
Benjamin, LJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (02) :447-451
[10]   PULSE OXIMETRY IN SICKLE-CELL DISEASE [J].
PIANOSI, P ;
CHARGE, TD ;
ESSELTINE, DW ;
COATES, AL .
ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 68 (06) :735-738