PVC membrane ion-selective electrodes for the determination of hyoscyamine in pure solution and in pharmaceutical preparations under batch and flow modes

被引:20
作者
Badawy, SS [1 ]
Issa, YM [1 ]
Mutair, AA [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Giza, Egypt
关键词
hyoscyamine; ion-selective electrodes; flow injection analysis; potentiometry;
D O I
10.1016/j.jpba.2005.03.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New PVC membrane electrodes selective for the determination of hyoscyamine ion (Hy(+)) based on hyoscyamine tetraphenylborate (Hy-TPB) or hyoscyamine phosphotungstate (Hy-PT) ion-exchangers as electroactive materials are described. The electrodes show a linear response for Hy(+) over the concentration range of 1.00 x 10(-5) to 1.26 x 10(-2) mol L-1 and 1.00 x 10(-1) to 1.00 x 10(-2) mol L-1 in case of Hy-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 1.00 x 10(-5) to 4.52 x 10(-3) mol L-1 and 6.31 x 10(-5) to 1.00 x 10(-2) mol L-1 in case of Hy-PT electrode for batch and FIA, respectively. The lower detection limits are 3.90 x 10(-6) and 4.51 x 10(-6) at 25 degrees C for Hy-TPB and Hy-PT electrodes, respectively. The electrodes posses near Nernstian slopes of 56.5 and 57.8 mV/decade for Hy-TPB and Hy-PT electrodes, respectively, and a fast potential response of <= 20s which is almost constant over a pH range of 3-10. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components, other than hyoscyamine, of the mixed drugs investigated show negligible interference. The electrodes have been applied to the potentiometric determination of hyoscyamine in pure solution and in pharmaceutical preparations under batch and FIA conditions and as end point indicator electrode for the determination of hyoscyanine using potentiometric titration. For the concentrations (1.08 x 10(-5) mol L-1 to 3.16 x 10(-3) mol L-1) an average recovery of 99.95% with relative standard deviation of 0.63% has been achieved. The effect of temperature on the electrodes was also studied. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 2002, MARTINDALE EXTRA PHA, P1067
[2]   ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF METOCLOPRAMIDE [J].
BADAWY, SS ;
SHOUKRY, AF ;
ISSA, YM .
ANALYST, 1986, 111 (12) :1363-1365
[3]  
BUCK RP, 1994, PURE APPL CHEM, V66, P227
[4]   RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58
[5]  
COSOFRET VV, 1992, PHARM APPL MEMBRANE, P448
[6]   Iron(III)-selective membrane potentiometric sensor based on 5,10,15,20-tetrakis(pentafluorophenyl)-21H, 23H-porphyrin [J].
Fakhari, AR ;
Alaghemand, M ;
Shamsipur, M .
ANALYTICAL LETTERS, 2001, 34 (07) :1097-1106
[7]  
Gupta AP, 1999, J INDIAN CHEM SOC, V76, P277
[8]   DETERMINATION OF STEREOISOMERS BY CIRCULAR-DICHROISM [J].
HAN, SM ;
PURDIE, N .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :455-458
[9]   Determination of L-hyoscyamine in atropine and D-hyoscyamine in L-hyoscyamine by chiral capillary electrophoresis as an alternative polarimetry [J].
Heine, S ;
Ebert, K ;
Blaschke, G .
ELECTROPHORESIS, 2003, 24 (15) :2687-2692
[10]  
Hiraoka N, 1996, BIOL PHARM BULL, V19, P1086, DOI 10.1248/bpb.19.1086