Intensity-modulated radiation therapy: Supportive data for prostate cancer

被引:105
作者
Cahlon, Oren [1 ]
Hunt, Margie [2 ]
Zelefsky, Michael J. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
D O I
10.1016/j.semradonc.2007.09.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Since its introduction into clinical use in the mid-1990s, intensity-modulated radiation therapy (IMRT) has emerged as the most effective and widely used form of external-beam radiotherapy for localized prostate cancer. Multiple studies have confirmed the importance of delivering sufficiently high doses to the prostate to achieve cure. The dosimetric superiority of IMRT over conventional techniques to produce conformal dose distributions that allow for organ sparing has been shown. A growing number of reports have confirmed that IMRT is the safest way to deliver high doses of external-beam irradiation to the prostate and the regional lymph nodes. Advances in imaging and onboard verification systems continue to advance the capabilities of IMRT and have potential implications with regards to further dose escalation and hypofractionated regimens. The clinical data in support of IMRT and the associated technical aspects of IMRT treatment planning and implementation are highlighted in this review. © 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:48 / 57
页数:10
相关论文
共 87 条
[1]   LOCALIZATION OF THE PROSTATIC APEX FOR RADIATION TREATMENT PLANNING [J].
ALGAN, O ;
HANKS, GE ;
SHAER, AH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (04) :925-930
[2]   Integral radiation dose to normal structures with conformal external beam radiation [J].
Aoyama, H ;
Westerly, DC ;
Mackie, TR ;
Olivera, GH ;
Bentzen, SM ;
Patel, RR ;
Jaradat, H ;
Tome, WA ;
Ritter, MA ;
Mehta, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (03) :962-967
[3]   Whole pelvic radiotherapy for prostate cancer using 3D conformal and intensity-modulated radiotherapy [J].
Ashman, JB ;
Zelefsky, MJ ;
Hunt, MS ;
Leibel, SA ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (03) :765-771
[4]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[5]   The getug 70 GY vs. 80 GY randomized trial for localized prostate cancer:: Feasibility and acute toxicity [J].
Beckendorf, V ;
Guérif, S ;
Le Prisé, E ;
Cosset, JM ;
Lefloch, O ;
Chauvet, B ;
Salem, N ;
Chapet, O ;
Bourdin, S ;
Bachaud, JM ;
Maingon, P ;
Lagrange, JL ;
Malissard, L ;
Simon, JM ;
Pommier, P ;
Hay, MH ;
Dubray, B ;
Luporsi, E ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1056-1065
[6]   Optimized planning using physical objectives and constraints [J].
Bortfeld, T .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :20-+
[7]   Secondary cancer after radiotherapy for prostate cancer: Should we be more aware of the risk? [J].
Bostrom, Peter J. ;
Soloway, Mark S. .
EUROPEAN UROLOGY, 2007, 52 (04) :973-982
[8]  
Brenner DJ, 2000, CANCER, V88, P398, DOI 10.1002/(SICI)1097-0142(20000115)88:2<398::AID-CNCR22>3.0.CO
[9]  
2-V
[10]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873