Software Lock Mass by Two-Dimensional Minimization of Peptide Mass Errors

被引:120
作者
Cox, Juergen [1 ]
Michalski, Annette [1 ]
Mann, Matthias [1 ]
机构
[1] Max Planck Inst Biochem, D-82152 Martinsried, Germany
关键词
Mass accuracy; MaxQuant; Proteomics; Database search; Orbitrap; Peptide mass measurement; Lock mass; ELECTROSPRAY-IONIZATION SOURCE; ACCURACY; NANOELECTROSPRAY;
D O I
10.1007/s13361-011-0142-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass accuracy is a key parameter in proteomic experiments, improving specificity, and success rates of peptide identification. Advances in instrumentation now make it possible to routinely obtain high resolution data in proteomic experiments. To compensate for drifts in instrument calibration, a compound of known mass is often employed. This 'lock mass' provides an internal mass standard in every spectrum. Here we take advantage of the complexity of typical peptide mixtures in proteomics to eliminate the requirement for a physical lock mass. We find that mass scale drift is primarily a function of the m/z and the elution time dimensions. Using a subset of high confidence peptide identifications from a first pass database search, which effectively substitute for the lock mass, we set up a global mathematical minimization problem. We perform a simultaneous fit in two dimensions using a function whose parameterization is automatically adjusted to the complexity of the analyzed peptide mixture. Mass deviation of the high confidence peptides from their calculated values is then minimized globally as a function of both m/z value and elution time. The resulting recalibration function performs equal or better than adding a lock mass from laboratory air to LTQ-Orbitrap spectra. This 'software lock mass' drastically improves mass accuracy compared with mass measurement without lock mass (up to 10-fold), with none of the experimental cost of a physical lock mass, and it integrated into the freely available MaxQuant analysis pipeline (www.maxquant.org).
引用
收藏
页码:1373 / 1380
页数:8
相关论文
共 18 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Andromeda: A Peptide Search Engine Integrated into the MaxQuant Environment [J].
Cox, Juergen ;
Neuhauser, Nadin ;
Michalski, Annette ;
Scheltema, Richard A. ;
Olsen, Jesper V. ;
Mann, Matthias .
JOURNAL OF PROTEOME RESEARCH, 2011, 10 (04) :1794-1805
[3]   Computational Principles of Determining and Improving Mass Precision and Accuracy for Proteome Measurements in an Orbitrap [J].
Cox, Juergen ;
Mann, Matthias .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) :1477-1485
[4]   A practical guide to the MaxQuant computational platform for SILAC-based quantitative proteomics [J].
Cox, Juergen ;
Matic, Ivan ;
Hilger, Maximiliane ;
Nagaraj, Nagarjuna ;
Selbach, Matthias ;
Olsen, Jesper V. ;
Mann, Matthias .
NATURE PROTOCOLS, 2009, 4 (05) :698-705
[5]   MaxQuant enables high peptide identification rates, individualized p.p.b.-range mass accuracies and proteome-wide protein quantification [J].
Cox, Juergen ;
Mann, Matthias .
NATURE BIOTECHNOLOGY, 2008, 26 (12) :1367-1372
[6]  
Fenn J., 1986, P 34 ASMS CINC OH, P507
[7]   A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry [J].
Hannis, JC ;
Muddiman, DC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (10) :876-883
[8]   MSQuant, an Open Source Platform for Mass Spectrometry-Based Quantitative Proteomics [J].
Mortensen, Peter ;
Gouw, Joost W. ;
Olsen, Jesper V. ;
Ong, Shao-En ;
Rigbolt, Kristoffer T. G. ;
Bunkenborg, Jakob ;
Cox, Juergen ;
Foster, Leonard J. ;
Heck, Albert J. R. ;
Blagoev, Blagoy ;
Andersen, Jens S. ;
Mann, Matthias .
JOURNAL OF PROTEOME RESEARCH, 2010, 9 (01) :393-403
[9]   Statistical evaluation of internal and external mass calibration laws utilized in Fourier transform ion cyclotron resonance mass spectrometry [J].
Muddiman, DC ;
Oberg, AL .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2406-2414
[10]   Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry [J].
Nepomuceno, AI ;
Muddiman, DC ;
Bergen, HR ;
Craighead, JR ;
Burke, MJ ;
Caskey, PE ;
Allan, JA .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3411-3418