Tissue response to bioabsorbable self-reinforced polylevolactide and polyglycolide pins implanted intra-articularly and directly into the bone on different levels - An experimental study on rats

被引:15
作者
Koskikare, K
Toivonen, T
Rokkanen, P
机构
[1] Univ Helsinki, Cent Hosp, Dept Orthopaed & Traumatol, FIN-00260 Helsinki, Finland
[2] Cent Hosp Kymenlaakso, Dept Pathol, Kotka, Finland
关键词
D O I
10.1007/s004020050336
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Self-reinforced poly-L-lactide (SR-PLLA) and self-reinforced polyglycolide (SR-PGA) pins were implanted intra-articularly and directly into the bone of the distal femur of rats at three levels: above, on the same level, and under the surface. For the controls only channels were drilled, or the controls were not operated at all. The follow-up times were 3, 6, and 12 weeks for SR-PGA and 3, 6, 12, and 24 weeks for SR-PLLA. The macroscopic appearance and histologically the villus reaction, the mononuclear phagocytosis and giant cells, the neutrophils, the lymphocytes, the plasma cells, the eosinophils, and the mast cells were analyzed. In the histologic analysis, the most favorable implantation depth was found to be under the surface where the contact between the implants and bone was best, and the orifice was covered with new trabecular bone at 3 weeks. This was especially seen in intra-articular implantation. In general, the tissue responses were mild, and could also be explained in the statistical analysis by a normal postoperative tissue response and faster biodegradation of PGA.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 20 条
[1]  
BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
[2]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[3]   DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB ;
NIEUWENHUIS, P ;
JANSEN, HWB .
BIOMATERIALS, 1991, 12 (01) :32-36
[4]   RESTORATION OF TISSUE-COMPONENTS AFTER INSERTION OF ABSORBABLE FRACTURE FIXATION DEVICES OF POLYGLYCOLIDE THROUGH THE ARTICULAR SURFACE - AN EXPERIMENTAL-STUDY IN THE DISTAL RABBIT FEMUR [J].
BOSTMAN, O ;
PAIVARINTA, U .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (03) :403-411
[5]  
BOSTMAN OM, 1995, CLIN ORTHOP RELAT R, P101
[6]  
Eitenmuller J, 1996, CHIRURG, V67, P413
[7]   SEVERE ASEPTIC SYNOVITIS OF THE KNEE AFTER BIODEGRADABLE INTERNAL-FIXATION - A CASE-REPORT [J].
FRIDEN, T ;
RYDHOLM, U .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :94-97
[8]  
HOLLINGER JO, 1986, CLIN ORTHOP RELAT R, P290
[9]   FIXATION STRENGTH OF A BIODEGRADABLE SCREW IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
KOUSA, P ;
JARVINEN, TLN ;
POHJONEN, T ;
KANNUS, P ;
KOTIKOSKI, M ;
JARVINEN, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (06) :901-905
[10]  
KUMAR V, 1992, BASIC PATHOLOGY, P130